The scope of the study is basically limited to the analysis of the present market for skincare product and consumer preference for purchasing skin care products. Scope in this section is ver…Full description
psychologyFull description
Transformers used to supply IT equipment and other non-linear loads need to be de-rated to between 60 and 80% of their nominal capacity. This technical note explains why, and how to determine the c...
The organization is the collection of people who cooperate in achieving the objectives which people have different behavior in work and needed a good education that should be owned by the Organization so that all employees that is in these organizati
Full description
Different factors that can influence impusle buying
Full description
Factors that influence market fluctuations
Laws That Affect Business in IndiaFull description
paper
The Hypnotic Abundance Affect (1)
brief description about external factors affecting retail industryFull description
a detailed research on box officeFull description
Five Key Factors That Influence Acidity
Fostering entrepreneurship needs a twofold policy that should focus on both the current situation and future prospect of entrepreneurship. Although many scholars and policy makers devote the…Full description
The quality of teaching and learning is determined not just by the quality of teachers, but also the quality of the environment where they are working. This study aims to track the motivational factors of basic education educator. The results show th
Affect Attunement in the Caregiver-Infant Relationship and Across Species Expanding the Ethical Scope of Eros Cynthia Willett
The quality of teaching and learning is determined not just by the quality of teachers, but also the quality of the environment where they are working. This study aims to track the motivational factors of basic education educator. The results show th
Factors that affect the efficiency of transformers
The heating effect of current in a coil. Power is lost as heat I2R whereby I is the current flowing through the coil and R is the resistance of the coil Methods to increase the efficiency Use thick copper wires of low resistance. Use coolant to decrease the temperature of the transformer.
Heating effect of induced eddy currents In the iron core. When the magnetic field in the iron core fluctuates, eddy currents are generated in the iron core. Methods to increase the efficiency Use a laminated iron core whereby each layer is insulated with enamel paint to prevent the flow of eddy currents. The high resistance between layers of the iron core decrease the prevalence of eddy currents and heat.
Magnetization of the iron core. The energy used in the magnetization and de-magnetization of the iron core each time current changes its direction is known as hysterisis. This energy is lost as heat which subsequently heats up the iron core. Methods to increase the efficiency Use a soft iron core that is easily magnetized and de-magnetized.
Flux leakage. Some of the induced magnetic flux from the primary coil is not transmitted to the secondary coil, therefore the e.m.f in the secondary coil is decreased. The secondary coil(windings) are intertwined tightly with the primary coils. The iron core should form a closed loop. Methods to increase the efficiency The secondary coil (windings) is intertwined tightly with the primary coils. The iron core should form a closed loop.
[This image is original released under GNU Free Documentation license ]
What is transformer? Transformer is a device that is used to raise or lower down the potential difference of an alternating current.
Function: The function of a transformer is to increase or decrease the potential difference of an alternating current supply.
Structure and Technical Terms 1. A transformer consist of 3 parts, namely 1. The primary circuit 2. The core 3. The secondary Circuit
[This image is released under the GNU Free Documentation License.]
Primary Circuit: The primary circuit is the circuit that connected to the input energy source. The current, potential difference and coil (winding) in the primary circuit are called the primary current (Ip), primary potential difference (Vp) and primary coil respectively. Core: The core is the ferromagnetic metal wound by the primary and secondary coil. The function of the core is to transfer the changing magnetic flux from the primary coil to the secondary coil. Secondary Circuit: The secondary circuit is the circuit that connected to the output of the transformer. The current, potential difference and coil (winding) in the secondary circuit are called the secondary current (Is), secondary potential difference (Vs) and secondary coil respectively.
Working Principle of A Transformer 1. A transformer consists of a primary coil and a secondary coil wound on a soft iron core. 2. When an alternating current flows in the primary coil, a changing magnetic flux is generated around the primary coil. 3. The changing magnetic flux is transferred to the secondary coil through the iron core. 4. The changing magnetic flux is cut by the secondary coil, hence induces an e.m.f. in the secondary coil. 5. The magnitude of the output voltage can be controlled by the ratio of the number of primary coil and secondary coil.
Types of Current in A Transformer The current in the primary circuit must be alternating current because alternating current can produce changing magnetic flux. A changing magnetic flux is needed to induce e.m.f. in secondary coil. The induced current in secondary is also an alternating current. The frequency of the alternating current in secondary coil is same as the frequency of the primary current. The alternating in the secondary circuit can be converted into direct current by using a pair of diode.
Symbol of A Transformer
The figure on the left shows the symbol of a transformer. The 2 lines in between the coil denote the core.
Types of Transformer Step-up transformer A step-up transformer is one where the e.m.f. in the secondary coil is greater than the e.m.f. in the primary coil. It is used to increases the potential difference. The number of windings in the secondary winding is greater than the number of windings in the primary coil. The current in the primary coil is greater than the current in the secondary coil. Step-down transformer Conversely, a step-down transformer is one where the e.m.f. in the secondary coil is less than the e.m.f. in the primary coil. It is used to reduce the potential difference. The number of windings in the primary winding is greater than the number of windings in the secondary coil. The current in the primary coil is lesser than the current in the secondary coil. Calculation of Potential Difference Change
Vp = input (primary) potential difference Vs = output (secondary) potential difference Ip = input (primary) current Is = output (secondary) current
Calculation of Current Change Ideal Transformer Non-ideal transformer
Vp = input (primary) potential difference Vs = output (secondary) potential difference Ip = input (primary) current Is = output (secondary) current
The heating effect of current in a coil. Power is lost as heat I2R whereby I is the current flowing through the coil and R is the resistance of the coil Methods to increase the efficiency Use thick copper wires of low resistance. Use coolant to decrease the temperature of the transformer.
Heating effect of induced eddy currents In the iron core. When the magnetic field in the iron core fluctuates, eddy currents are generated in the iron core. Methods to increase the efficiency Use a laminated iron core whereby each layer is insulated with enamel paint to prevent the flow of eddy currents. The high resistance between layers of the iron core decrease the prevalence of eddy currents and heat.
Magnetization of the iron core. The energy used in the magnetization and de-magnetization of the iron core each time current changes its direction is known as hysterisis. This energy is lost as heat which subsequently heats up the iron core. Methods to increase the efficiency Use a soft iron core that is easily magnetized and de-magnetized.
Flux leakage. Some of the induced magnetic flux from the primary coil is not transmitted to the secondary coil, therefore the e.m.f in the secondary coil is decreased. The secondary coil(windings) are intertwined tightly with the primary coils. The iron core should form a closed loop. Methods to increase the efficiency The secondary coil (windings) is intertwined tightly with the primary coils. The iron core should form a closed loop.