HVAC HANDBOOK
We endeavour to become the most responsible, the most future-oriented
and first first of all the most most innovative manufacturer in the world
Being responsible
is our foundation
Thinking ahead
makes mak es it poss possible ible
With an annual production of 10 million pump units, Grundfos is one of the world's leading manufacturers manufacturers of pumps. Currently Currently,, it is the world's largest largest manufacture manufacturerr of circulators,, with more than 50% of the world market. The product line includes pumps circulators and accessories for Water Supply, Plumbing/HVAC, Industrial, Environmental, and Wastewater products. Grundfos was was established in 1945 by the late Poul Due Jensen. Jensen. Initially Initially,, it was named Bjerringbro Die-Casting and Machine Factory, and in 1968 the name was changed to Grundfos. The word Grundfos means "ground "ground spring" in Danish. The Poul Due Jensen Foundation was established as a self-governing institution in 1975, shortly before Due Jensen's death in 1977. Today, the foundation owns own s 85% of the shares and the founder's family family owns the remaining 15% in Grundfos Holding AG. The aim of the foundation is to expand the economic base of the company and develop the Grundfos Group. The capital and profits profits of the foundation foundation are re-inves re-invested ted into Grundfos companies worldwide. The Grundfos Group is represented in over 40 countries through more then 60 companies. Each company is locally managed and operated, operated, and the products products are sold through distributors and wholesalers worldwide. The Group Management Management is headquartered in Bjerringbro, Bjerringbro, Denmark with Niels Due Jensen as the Group President. Grundfos Pumps Corporation (USA), establish established ed in 1973, is a member of the Grundfos Group and is headquartered in Olathe, Kansas. The North American Regional Headquarters is located in Olathe, KS with distribution centers in Allentown, PA and Fresno, CA. Outside of the USA, Grundfos Canada Inc. is situated in Toronto, Canada, and Grundfos Mexico is situated in Monterrey, Mexico.
Innovation
is the essance of all we do
TA BLE OF C O N TE NTS CO
............................... ..................... ..................... .................... ......... i2 Table of Contents .................... .............................. ..................... ............. ... i3 Applications / Specifications ................... ............................... ..................... .................. ........ i4 Performance at a Glance ....................
SECTION I Small Circulating Pump Quick Quick Fact Sheet .............. ...................... .............. ...... 1-1 UP Terminal Terminal Box and Nameplate Convention .............. ...................... .......... 1-3
Submittal Data Sheets Series Series Series Series Series
UP - Open System ............... ....................... ................ ............... ............... ............... ....... 1-5 UP - Closed Systems ............... ....................... ............... ............... ............... ........... .... 1-7 UP / 26-116 Sub Data ............... ....................... ................ ............... ............... .......... .. 1-9 UP / 50-75F Sub Data ................ ....................... ............... ............... .............. ....... 1-11 UP / BUC5 & BUC7 ............... ...................... ............... ............... ............... ............ .... 1-13
Series UP - Comfort ........................................................................................ 1-15
Series UP - MixiMizer ............................. ............................. ... 1-17 Series UP - TLC ......................................... .............................. 1-19 Series UP - Variable Speed .......................... .......................... 1-21 Flanges ....................... .......................... .......................... ........ 1-23 1-23 Timer Control ............... ...................... ............... ............... ............... ............... ............... ................ ............. ..... 1-25 1-25 AquaStat (Thermostatic (Thermostatic Control) ................ ....................... ............... ............... ........... .... 1-26 1-26 Series UP - Low Voltage Voltage Control ............... ....................... ............... ............... ............. ..... 1-27 1-27 Product & Flange Part Numbers ............... ....................... ............... ............... ............. ..... 1-28 1-28
SECTION IV Technical Data Plumbing & Heating Formulas Pump Formulas & Affinity Laws ............... ....................... ............... ............... ............... ....... 4-1 Conversi ons ............... ...................... ............... ............... ............... ................ ............... ............... ............... ....... 4-2 NPSH (Net Positive Suction Head) ............... ....................... ............... ............... .......... 4-3 Barometric Readings & Atmospheric Pressures Corresponding to Different Altitudes ............... ...................... ............... ............... ............... ................ ............... ............... ............... ........... .... 4-3 NSPHA / Vapor Vapor Pressure..................... Pressure............................. ............... ............... ................ ............ .... 4-4 Properties of Water at Various Tempera tures ............... ...................... ............... ............... ............... ................ ............... ............... .......... .. 4-5 Freezing & Boiling Points of Aqueus Solutions of Ethylene Glycol ............... ....................... ............... ............... ................ ............ .... 4-6 Density of Aqueus Solutions of Ethylene Glycol Viscosity of Aqueus Solutions of Ethylene Glycol ............... ...................... ............... ............... ............... ................ ............... ............. ...... 4-7 Maximum Shock Pressure Caused by Water Hammer ............... ...................... ............... ............... ............... ................ ............... ............. ...... 4-9 Properties of Water at Various Temperatur Temperatures es ............... .................... ..... 4-10 Formu las ............... ....................... ................ ............... ............... ............... ............... ............... ............... ........... ... 4-11
SECTION II
Pipe Information Sheets (Steel & Copper) Copper) ............... ...................... ........... .... 4-14
Large Circulating Circulating Pump Quick Fact Fact Sheet ............... ...................... ............ ..... 2-1 Submittal Data Sheets VersaFlo ® / UPS32 ................ ....................... ............... ................ ............... ............... ............... ............ ..... 2-3 VersaFlo ® / UPS40 ................ ....................... ............... ................ ............... ............... ............... ............ ..... 2-5 VersaFlo ® / UPS50 ................ ....................... ............... ................ ............... ............... ............... ............ ..... 2-7 VersaFlo ® / UPS80&100 ................ ....................... ............... ............... ............... ............... ........... .... 2-9 VersaFlo ® / TP32 ............... ...................... ............... ................ ............... ............... ............... .............. ....... 2-11 VersaFlo ® / TP40 ............... ...................... ............... ................ ............... ............... ............... .............. ....... 2-13 VersaFlo ® / TP50 ............... ...................... ............... ................ ............... ............... ............... .............. ....... 2-15 VersaFlo ® / TP80 ............... ...................... ............... ................ ............... ............... ............... .............. ....... 2-17 VersaFlo ® / TP100 ............................. ............................... ........ 2-19 2-19 Product & Flange Part Numbers ............... ....................... ............... ............... ............. ..... 2-21 2-21
Pressure Loss ............... ....................... ................ ............... ............... ............... ............... ................ .......... .. 4-16 Friction of Water - Smooth Wall Copper Tubing, Brass, and Plastic Pipe (3/8” to 4”) ............... ....................... ............... ............... ................ ............... ............... ............... ........... .... 4-20 Friction of Water - New Steel Pipe (1/2” to 4”) ............... ...................... ............... ............... ............... ............... ............... ............... ............. ...... 4-28 Friction Losses Through Pipe Fittings and Valves Valves ............... ...................... ............... ............... ............... ............... ............... ............... ............. ...... 4-36 Hydronic Water Flow Calculator...................... Calculator............................. ............... ............. ..... 4-37 Heat Loss From From Bare Steel Pipe & Covered Covered Pipe ............. ............. 4-38 Typical Symbols ............... ...................... ............... ................ ............... ............... ................ ............... ....... 4-39 Circulator Replacement Replacement Guide (UP) ............... ...................... ............... ............. ..... 4-40
SECTION III Submittal Data Sheets Series L / 2.5LM5 ....................... ........................ ........................ 3-1 3-1 Series Series L / 2.5LM6 ................. .......................... ................. ................. .................. ................. ................. ......... 3-3 Series L / 2.5LM8 ............... ....................... ............... ............... ................ ............... ............... ............... ....... 3-5 Series L / 3.0LM5 ............... ....................... ............... ............... ................ ............... ............... ............... ....... 3-7 Series L / 3.0LM6 ............... ....................... ............... ............... ................ ............... ............... ............... ....... 3-9 Series L / 3.0LM8 ............... ....................... ............... ............... ................ ............... ............... ............. ..... 3-11 Series L / 2.5LP5 ............... ....................... ............... ............... ................ ............... ............... ............. ..... 3-13 Series L / 3.0LP5 ............... ....................... ............... ............... ................ ............... ............... ............. ..... 3-15 Series L / 3.0LP6 ............... ....................... ............... ............... ................ ............... ............... ............. ..... 3-17 Series L / 4.0LP5 ................................... ................................... 3-19 3-19 Product & Flange Part Numbers ............... ....................... ............... ............... ............. ..... 3-21 3-21
VersaFlo UPS/TP Cross Reference Gui de ............... ....................... ............... ............... ................ ............... ............... ................ ............... ............ ..... 4-41 Apartment/Condominiums/Office/Hospitals/Schools Capacity Sizing ............... ....................... ............... ............... ................ ............... ............... ............... ......... ..4-43 4-43 Blank Grids . ............... ....................... ............... ............... ............... ............... ............... ............... ............... ......... 4-48
t s e e t a a l e h h t r o n F o o i i t a , s s m m t r c o o u f d n u r p r o i n o o t g a n n i e e d d t t i r s a e g o u r W e b c r e o m c . t t s i o o s s i f v d n u u r g g w w w.
i -2
APPLIC ATIONS APPLICA
1
2
3
S E RI E S
SERIES
SERIES ®
UP
VersaFlo
CIRCULATORS
“L” “L”
PUMPS
PUMPS
BOILER/HYDRONIC HEATING CHILLED WATER CIRCULATION COOLING TOWERS DEAERATORS DOMESTIC DOMEST IC HOT WATER WATER DRAINAGE EFFLUENT FLUID TRANSFER FOUNTAINS GLYCOL SOLUTIONS GROUND SOURCE HEAT PUMPS HEAT PUMPS HOT WATER RECIRCULATION HOT WATER AIR HANDLING HVAC INDUSTRIAL MARINE SERVICE PAINT BOOTH PROCESS WATER QUENCH WATER RADIANT FLOOR HEAT SEWAGE SOLAR SUMP SWIMMING POOLS SNOW MELT SYSTEMS
SPEC ATIONS SPECIIFIC FICA Section In This Handbook
Capacity
in U.S. gpm
1
2
2
3
SERIES
SERIES
S E RI E S
SERIES
UP
VersaFlo ®
VersaFlo ®
“L” “L”
CIRCULATORS
PUMPS
PUMPS
PUMPS
0 - 46 gpm
9 - 270 gpm
8 to 300 gpm
30 - 600 gpm
Single:
Single:
UPS
TP
Total Head in feet
0 - 37.5 feet
1 - 62 feet
3.5 - 67.5 feet
8 - 180 feet
HP
1/25 to 1/6
1/3 to 3
1/3 to 3
3/4 to 20
Temp. Range Range
32°F - 230°F
14°F - 230°F
5°F - 288°F
5°F - 250°F
Max. Working Working Pressure Pressure
145 PSI
145 PSI
145 PSI
175 PSI
i -3
PER PE RFORMANC E AT A GL ANC AN CE ORMANCE GLAN
CIRCULATOR CURVES
FLOW IN U.S. GALLONS PER MINUTE
i -4
NOTE: Performance curves shown above are approximations only. For more detailed performance information, refer to the Submittal Data pages later in this book.
GRUNDFOS SERIES UP
S E C T I O N 1
QUICK FACT SHEET Small Circulating Pumps Series Ser ies UP1 UP15’ 5’s s • Ope Open n & Clo Closed sed Sys System tems s AVAILABLE MODELS (Closed Systems): • UPS15-42F UPS15-42F & FR (3 Speed) • UP15-42F UP15-42F & FR BRUTE II ® • UP UP15 15-4 -42F 2FC C & FRC FRC CONNECTIONS:
Flange, cast iron, (2) 1/2” diameter bolt holes
AVAILABLE MODELS (Open Systems): • UP15-10B5 • UP UP15-18B5 • UP15-10B7 • UP UP15-18B7 CONNECTIONS: B5 - Swea Sweatt fitt fittin ings gs,, Bron Bronze ze,, 1/2 1/2”” B7 - Swea Sweatt fitt fittin ings gs,, Bron Bronze ze,, 3/4” 3/4” FLOW RANGE: 0 to 20 gpm HEAD RANGE: 0 to 16.5 feet MOTOR: 2 pole, single phase
• UP15-10F & FR
• UP UP15-18SU & SF • UP UP15-42SU & SF • UPS15-42SU UPS15-42SU & SF
• UP UP15-42B5 • UP UP15-42B7
SU - Uni Union on,, sta stain inle less ss stee steel, l, 1-1/ 1-1/4” 4” NP NPSM SM SF - Fla Flang nge, e, stain stainle less ss steel steel,, (2) (2) 1/2 1/2”” diam diam.. bol boltt hole holes s
MAXIMUM FLUID TEMPERATURE (Open Systems): 220° 22 0°F* F* (10 ( 104° 4°C) C) (Closed Systems): 230° 23 0°F F (110 ( 110° °C)
MINIMUM FLUID TEMPERATURE: 36° 36 °F (2° (2°C) C) PRESSURE: 145 psi maximum (working)
Serie Se ries s UP26 UP26’’s • Ope Open n & Clos Closed ed Syst Systems ems AVAILABLE MODELS (Closed Systems): • UP26-64F • UP26-96F • UP UP2 26-1 6-116F 16F CONNECTIONS:
• UP26-99F
• UP43-75F
Flange, cast iron, (2) 1/2” diameter bolt holes
AVAILABLE MODELS (Open Systems): • UP25-64SU & SF • UP26-96BF • UP UP26 26-1 -116 16BF BF
• UP UP26-99BF
• UP43-75BF
CONNECTIONS: SU - Uni Union on,, sta stain inle less ss stee steel, l, 1-1/ 1-1/4” 4” NP NPSM SM BF - Fla Flang nge, e, bron bronz ze, (2) (2) 1/2 1/2”” dia diam. m. bolt bolt hole holes s SF - Flange, stainless steel, (2) 1/2” diam. bolt holes FLOW RANGE: 0 to 46 gpm HEAD RANGE: 0 to 37.5 feet MOTOR: 2 pole, single phase
MAXIMUM FLUID TEMPERATURE (Open Systems): 220° 22 0°F* F* (10 ( 104° 4°C) C) (Closed Systems): 230° 23 0°F F (110 ( 110° °C)
MINIMUM FLUID TEMPERATURE: 32° 32 °F (0° (0°C) C) PRESSURE: 145 psi maximum (working)
Ser erie ies s UP UP • BU BUC C5 & BUC BUC7 7
AVAILABLE MODELS: UP UP15 15-1 -18B 8BUC UC5 5 • UP UP15 15-4 -42B 2BUC UC5 5 • UP UP15 15-1 -18B 8BUC UC7 7 • UP UP15 15-4 -42B 2BUC UC7 7 CONNECTIONS: • BUC5 = 1/2” 1/2” copper copper pipe, female female sweat sweat fittings fittings • BUC7 = 3/4” 3/4” copper copper pipe, female female sweat sweat fittings fittings
FLOW RANGE: 0 to 16 gpm HEAD RANGE: 0 to 15 feet MOTOR: 2 pole, single phase MAXIMUM FLUID TEMPERATURE: 200° 200°F* F* (93° ( 93°C) C) MINIMUM FLUID TEMPERATURE: 36° 36 °F (2° (2°C) C) PRESSURE: 145 psi max. (working)
*NOTE: It is recomm ended to keep the operat ing temperature as low as possible (ie., below 140°F, 60°C 60°C to avoid precipitat ion of calcium).
1-1
Grundfos Circulators Serie Se ries s UP • 50 50-75 -75F F Clos Closed ed Sy Syste stem m FLANGE: 2” slotted, 4-bolt FLOW RANGE: 0 to 45 gpm HEAD RANGE: 0 to 26 feet MODEL: UP50-75F, 60 Hz MOTOR: 2 pole, single phase
MATERIALS OF CONSTRUCTION: DESCRIPTION (Closed) Shaf Shaft, t, Uppe Upperr & Low Lower er Radi Radial al Bearings Thrust Bearing O-ring & Gaskets Impeller
MAXIMUM FLUID TEMPERATURE: 230° 230 °F (11 (110° 0°C) C) MINIMUM FLUID TEMPERATURE: 32° 32 °F (0° (0°C) C) PRESSURE: 145 psi maximum (working)
Closed Systems & Open Systems
MAT E RI AL Alum Alumin inum um Oxid Oxide e C e ra m i c Metal Impregnated Carbon EP (Ethylene Propylene Rubber) PES Composite (30% Glass Filled)
DESCRIPTION (Open) Inlet Cone, Bearing Plate, Bear Bearin ing g Reta Retain iner ers, s, Roto Rotorr Can, Can, Rotor Cladding, Shaft Retainer, Check Valve Spring on (UP BUC5 & BUC7) Volute Retainer (SU & SF Models) & Stator Housing Pump Housing (Volute ) Union Gasket on BUC5 & B UC 7 Tail Piece & Union Nut on BUC5 & BUC7 Teminal Box Check Va Valve Ho Housing, Va Valve and Torpedo
M ATE RI AL Stainless Steel 304 304
Aluminum Silicon Br B ronze (c875) or 304SS or Cast Iron Non As A sbestos Fiber B rass (UNS C36000) Noryl ® P OM OM (Polyoxymehtylene )
Noryl ® is a registered trademark of General Electric Company. BRUTE II ® is a registered trademark of Grundfos Pumps Corporation.
L-PH-Q L-PH-QFF-00 002 2 Rev. 01/01 PRINTED IN USA
1-2 12
e t a l p e m a N d n o n i a t n x e o v B n l o a C n i m r e T P U
p n U o g i t i n H n p 9 H 2 e m : 1 v u x o : e n P B t o : l l a C n a p n e t i o i n t m m r a a e t e r N r n T e u i r C O
B T n m o w r o f n D 2 e o g B i s i t i n w n p T : k c e m x o o v u B l n P l C o : a ° n 0 C n i 7 o m r i t r 2 o i a e : e t r T t a P n e l i p r e O m a N
1-3 13
1-4 14
Series UP OPEN SYSTEMS
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
FE ET
VOLT
PHASE
COMMENTS
Mounting Positions
Technical Data FLOW RANGE: 0 to 46 U.S. GPM MIN. FLUID TEMPERATURE for UP15: 36°F (2°C) HEAD RANGE: 0 to 32 Feet MIN. FLUID TEMPERATURE for ALL OTHERS: 32°F (0°C) MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 220°F 220°F (104°C), (104°C), Maximum Maxi mum design desig n temperature. temperatu re. FOR OPEN SYSTEMS - 140°F 140°F (60°C) (60°C) Is the maximum maxi mum recommende d fluid temperature temp erature to avoid precipitation of calcium in water. FOR CLOSED SYSTEMS - 230°F (110°C) Ambi Ambien entt Air Air Temp Temp.. 130° 130°F (55 (55° °C) 140° 140°F (60 (60° °C) 160° 160°F (71 (71° °C) 175° 175°F (79 (79° °C) Maximum Maximum Water Water Temp. Temp. 220°F (104° (104°C) 210°F (99° (99°C) 190°F (88° (88°C) 175°F (79° (79°C) MAXIMUM WORKING PRESSURE: 145 PSI MINIMUM REQUIRED INLET PRESSURE: Temp Temper erat atur ure e 220° 220°F (104 (104° °C) 190° 190°F (88° (88°C) 140° 140°F (60° (60°C) Pressure 36 Ft. (11m) 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 15.6 psi 4.0 psi 1.3 psi
®
Recommended
DO NOT Optional
Mount Motor Shaft in Vertical Position
FOR INDOOR USE ONLY
Dimensions, and Weights
UP26-96BF, UP26-99BF, & UP43-75BF
UP15-18SF, UP15-42SF, UPS15-42SF & UP25-64SF
UP15-18SU, UP15-42SU, UPS15-42SU & UP25-64SU
F
UP15-10B5 & B7, UP15-18B5 & B7, UP15-42B5 & B7
A
B
C
D
E
UP15-10B5
5
4 11 / 16 16
4
4
3 1 / 2
—
Sweat – 1 / 2"
6
UP 15-10B 7
6 3 / 8
5 1 / 8
4
3 13 / 16 16
3 1 / 4
—
Sweat – 3 / 4"
6. 7
UP15 UP15-1 -18S 8SU U & UP/ UP/UP UPS1 S155-42 42SU SU
5 7 / 8
5 1 / 16 16
4
3 7 / 16 16
3 1 / 4
—
Union – 1 1 / 4" NPSM
UP15 UP15-1 -18S 8SF F & UP/U UP/UPS PS15 15-4 -42S 2SF F
3 16 16
5
6 /
5 /
4
4 /
3 /
UP15-18B5 & UP15-42B5
5
4 11 / 16 16
4
3 1 / 2
3 1 / 4
—
Sweat – 1 / 2"
UP15-18B7 & UP15-42B7
6 3 / 8
5 1 / 8
4
3 13 / 16 16
3 1 / 4
—
Sweat – 3 / 4"
UP 25 -64S U
7
5 / 8
13
5 / 16 16
13
4 / 16 16
4
3 / 2
—
Union – 1 / 4" NPSM
U P 25-6 4S F
1
6 / 2
1
6 / 16 16
13
4 / 16 16
3
4 / 16 16
1
3 / 2
5
3 / 32 32
Flange – (2) / 2" Dia. Bolt Holes
10
U P 26-9 6B F
6 1 / 2
6 3 / 8
5 1 / 16 16
4 1 / 8
3 1 / 2
3 5 / 32 32
Flange – (2) 1 / 2" Dia. Bolt Holes
12.5
U P 26-9 9B F
6 1 / 2
6 3 / 8
5 1 / 16 16
4 1 / 8
3 1 / 2
3 5 / 32 32
Flange – (2) 1 / 2" Dia. Bolt Holes
12.5
U P 43-7 5B F
8 /
6 /
5 /
4 /
3 /
3 /
Flange – (2) / " Dia. Bolt Holes
15
NOTES: All dimensions are in inches.
1 2
1 2
1 4
11 16 16
3 16 16
3 4
1 4
1
1 2
3 /
Connection Type and Size
Shipping Wt. (Lbs.)
OPEN SYSTEM MODELS
5 32 32
Flange – (2) / " Dia. Bolt Holes
6 6 6. 7
7 16 16
"F" dimension is the flange bolt centerline to centerline.
1 2
1
1
1 2
9
1-5
Performance
Stainless Steel or Bronze Construction - Flange, Union, or Sweat Mount UP 15-42 B5 UP 15-18 B5 3 UP 15-10 B5 1
UP 15-42 B7 UP 15-18 B7 6 UP 15-10 B7 4
2
1
) . T F ( D A E H
5
4
) . T F ( D A E H
2
5
6
3
CAPACITY (U.S. GPM)
CAPACITY (U.S. GPM) UP 26-99 BF 11 UP 43-75 BF 9 UP 26-96 BF 12 10UP 25-64 SU & SF 11UP 15-42 SU & SF 13 12 UPS 15-42 SU & SF Spd. 3 13UPS 15-42 SU & SF Spd. 2 11 2 14UP 15-18 SU & SF 15 UPS 15-42 SU & SF Spd. 1 15 7 8
7
) . T F ( D A E H
8
9
Note: Performance shown is for 115V models. 230V models will 16 vary slightly.
10
13
12 14
12
11
15
12
CAPACITY (U.S. GPM)
Electrical Data MODEL UP15-10B5 & B7 UP15-18SU, SF, & B5 UP15-18B7 UP15-42SU, SF, & B5 UP15-42B7
VOLTS 115 115 230 115 230 115 230 115 230
AMPS .55 .74 .40 .74 .40 .74 .41 .74 .41
WATTS 58 85 90 85 96 85 95 85 95
HP 1 / 25 25 1 25 / 25 1 25 / 25 1 25 / 25 1 25 / 25 1 25 / 25 1 25 / 25 1 25 / 25 1 25 / 25
CAPACITOR 8µF/180V 10µF/180V 2µF/400V 10µF/180V 2µF/400V 10µF/180V 2µF/400V 10µF/180V 2µF/400V
MODEL UP25-64SU & SF UP26-96BF UP26-99BF UP43-75BF
VOLTS
AMPS
WATTS
HP
CAPACITOR
115 230
1.70 .80
180 175
1
1 12 12
/ 12 12 /
8µF/180V 2.5µF/380V
115 230
1.70 .80
205 205
1
12 / 12 / 12 12
10µF/180V 2.5µF/380V
115 230
2.15 1.07
245 245
1
/ 6 /
10µF/180V 2.5µF/380V
115 230
2.15 1.07
215 220
1
10µF/180V 2.5µF/380V
1
1 6
/ 6 / 6
1
Materials of Construction DESCRIPTION
MATERIAL
DESCRIPTION
MATERIAL
Inlet Cone, Bearing Bearing Plate, Plate, Bearing Bearing Retainers, Retainers, Rotor Rotor Can, Rotor Cladding, Shaft Retainer.
304 Stainles Stainless s Steel
O'Ring & Gaskets
EP (Ethylene Propylene Rubber)
Pump Housing (Volute) Volute Retainer Retainer (SU & SF Models) Models) & Stator Stator Housing Housing
Alum Aluminu inum m
Silicone Bronze C875 or Stainless Steel
Shaft, Upper & Lower Radial Bearings
Aluminum Oxide Ceramic
Impeller
Thrust Bearing
Metal Impregnated Carbon
PES Composite (30% Glass Filled)
Terminal Box
® Noryl ®
1-6 16
L-UP-T L-UP-TL-0 L-007 07 Rev. Rev. 01/0 01/01 1 PRINTED IN USA
Series UP CLOSED SYSTEMS
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
FE E T
VOLT
PHASE
COMMENTS
Mounting Positions
Technical Data FLOW RANGE: 0 to 46 U.S. GPM MIN. FLUID TEMPERATURE for UP15: 36°F (2°C) HEAD RANGE: 0 to 32 Feet MIN. FLUID TEMPERATURE for ALL OTHERS: 32°F (0°C) MOTOR: 2Pole, Single Phase ® MAXIMUM FLUID TEMPERATURE – CLOSED SYSTEMS: 230°F (110° (11 0°C) C)
Recommended
Ambi Ambien entt Air Air Temp Temp.. 95° 95°F (35° (35°C) 130° 130°F (55° (55°C) 140° 140°F (60 (60° °C) 160° 160°F (71 (71° °C) 175° 175°F (79 (79° °C) Maximum Maximum Water Water Temp. Temp. 230°F (110°C) 220°F (104°C) 210°F (99°C) 190°F (88°C) 175°F (79°C) MAXIMUM WORKING PRESSURE: 145 PSI
MINIMUM REQUIRED INLET PRESSURE 230°F 230°F (110°C) (110°C)
190°F 190°F (88°C) (88°C)
140°F 140°F (60°C) (60°C)
Feet of Water Inlet Pressure
36 Ft. Ft. (1.1 (1.10m 0m)) 15.6 psi
9.0 9.0 Ft. Ft. (2.8 (2.8m) m) 4.0 psi
3.0 3.0 Ft. Ft. (0.9 (0.9m) m) 1.3 psi
Dimensions, Dimensions , and Weights B
DO NOT
Fluid Temp
B
C
FOR INDOOR USE ONLY B
C
E
Mount Motor Shaft in Vertical Position
Optional
C
E
E D
D
D
A
F
A
F
A
F
UP15-42FR UPS15-42FR
UP15-42F/FC UPS15-42F
CLOSED SYSTEM MODELS
A
B
C 4
4 3 / 16 16
3 1 / 4
3 5 / 32 32
Flange – (2) 1 / 2" Dia. Bolt Holes
7 1 / 4
®
UP15-FR (BRUTE II ) & UPS15-42FR
1
6 / 2
15
5 / 16 16
4
3
3 / 4
1
3 / 4
5
3 / 32 32
Flange – (2) / 2" Dia. Bolt Holes
7 1 / 4
UP15-4 UP15-42FC 2FC (*Brut (*Brute e II II w/ w/ c chec heck k valv valve) e)
6 1 / 2
5 1 / 4
4
4 3 / 16 16
3 1 / 4
3 5 / 32 32
Flange – (2) 1 / 2" Dia. Bolt Holes
7 1 / 4
UP26-64F & UP26-96F
6 1 / 2
6 3 / 8
5 1 / 16 16
4 1 / 8
3 1 / 2
3 5 / 32 32
Flange – (2) 1 / 2" Dia. Bolt Holes
11 1 / 4
UP26-99F
6 /
6 /
1 16 16
5 /
1 8
4 /
3 /
5 32 32
3 /
Flange – (2) / " Dia. Bolt Holes
12 1 / 2
UP43-75F
8 1 / 2
6 11 / 16 16
5 3 / 16 16
4 3 / 4
3 1 / 2
3 7 / 16 16
Flange – (2) 1 / 2" Dia. Bolt Holes
13 1 / 2
NOTE NOTES: S:
All dimensi dimensions ons are in inches inches..
3 8
1 2
F
Connection Type and Size
Shipping Wt. (Lbs.)
5 1 / 4
1 2
E
À
6 1 / 2
UP15-42F (BRUTE II ® ) & UPS15-42F
D
UP26/43
1
1 2
¬
"F" dimension is the flange bolt centerline to centerline.
*Criculators w/ check valve have a maximum water temperature of 200°F.
1-7
Performance Curves Cast Iron Construction – Flange Mount
Note: Performance shown is for 115V Models. 230V models will vary slightly.
Electrical Data MODEL UP15-42F/FR/FC (BRUTE II ® )
VOLTS 115 230
UPS15-42F Spd. 3 (115V) S pd. 2 S pd. 1
115 -----
.74 .57 .40
85 65 45
1
UPS15-42F Spd. 3 (230V) S pd. 2 S pd. 1
230 -----
.43 .19 .14
95 40 30
1
NOTE:
AMPS .74 .43
WATTS 85 95
HP 1 / 25 25 1 25 / 25
CAPACITOR 10µF/180V 2µF/400V
/ 25 25 ---- / 25 25 -----
MODEL
VOLTS
AMPS
WATTS
HP
CAPACITOR
12 12 1 12 12
/ /
8µF/180V 2.5µF/380V
UP26-64F
115 230
1.70 .80
185 175
1
10µF/180V -----
UP26-96F
115 230
1.70 .80
205 205
1
/ /
10µF/180V 2.5µF/380V
UP26-99F
115 230
2.15 1.07
245 245
1
/ /
10µF/180V 2.5µF/380V
2µF/400V -----
UP43-75F
115 230
2.15 1.07
215 220
1
10µF/180V 2.5µF/380V
12 12 1 12 12 6 1 6
/ /
6 1 6
All UP models are single speed except for the 3-speed UPS15-42F, 115 and 230 volt.
Materials of Construction DESCRIPTION
MATERIAL
Inlet Inlet Cone, Cone, Bear Bearing ing Plat Plate, e, Beari Bearing ng Retai Retainer ners, s, Rotor Can, Rotor Cladding, Shaft Retainer
304 Stai Stainle nless ss Steel Steel
Stator Housing Shaf t,t, Up Up pe per & Low er er Ra Rad ia ial Be Bea riri ng ngs T h r u st B e a r i n g Check Valve
Aluminum Al um umi nu nu m Ox id id e C er er am am ic ic Metal Impregnated Carbon ACETAL Wi th 302 Stainless Steel Spring & Nitrile Rubber Seats
DESCRIPTION Pump Housing (Volute)
MATERIAL C a st I r o n
O'Ri ng & Gaskets
EP (Ethylene Propylene Rubber) PES Composite (30% Glass Filled)
Impeller Terminal Box
® Noryl ®
® is a registered ® is a registered trademark of Grundfos Pumps Corporation. NOTE: Noryl ® registered trademar trademark k of General General Electric Electric Company. Company. BRUTE BRUTE II ®
1-8 18
L-UP-T L-UP-TL-1 L-107 07 Rev.12/00 12/00 PRINTED IN USA
UP
26-116
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
F E ET
VOLT
PHASE
Technical Data
COMMENTS
Mounting Positions
HEAD RANGE: 0 – 37.5 Feet
CONNECTION TYPE & SIZE: Flange - (2)-1/2” Dia. Bolt Holes
MOTOR: 2 Pole, Single Phase, PSC
MINIMUM REQUIRED INLET PRESSURE:
FLOW RANGE: 0 – 38.5 U.S. GPM
MINIMUM FLUID TEMPERATURE: 32°F (0°C)
Recommended
Fluid Fluid Temp. Temp. 150° 150°F (65. (65.5° 5°C) 140° 140°F (60° (60°C) Feet of Water 4 Ft. 3 Ft. Inlet Pressure 1.7 psi 1.3 psi
MAXIMUM FLUID TEMPERATURE: 150°F (65°C) MAXIMUM WORKING PRESSURE: 145 PSI (10 Bars)
Optional
DO NOT Mount Motor Shaft in Vertical Position
FOR INDOOR USE ONLY
Materials of Construction
Performance Curves
Inlet Inlet Cone, Bearin Bearing g Plate, Plate, Bearing Bearing Retainer Retainers, s, Rotor Can, Rotor Cladding, Shaft Retainer I m pe l l e r Stator Housing Shaf Shaft, t, Uppe Upperr and and Lowe Lowerr Rad Radia iall Bea Beari ring ngs s Thrust Bearing Pump Housing (volute) O-Ring and Gaskets Terminal Box
) . T F ( D A E H
304 Stainle Stainless ss Steel Steel PES Composite (30% Glass Filled) A l um i n um Alum Alumin inum um Oxid Oxide e Cer Ceram amic ic Metal Impregnated Carbon Cast Iron or Silicon Bronze C875 EP (Ethylene Propylene Rubber) No ryl®
® is a registered trademark of General Electric Company Note: Noryl ®
Nomenclature Circulator Pump
UP
26
-1 16 B
F Flange Bronze
Nominal diameter of ports in mm
CAPACITY (U.S. GPM)
Maximum head in meters x 10
Dimensions and Weight MODEL A UP26-116F & BF 6-1/2
B 6-3/8
C 5 -1 / 1 6
D 4 - 1/ 8
E 3-1/ 2
Fx 3 -5 / 3 2
SHIP. WT. 12-1/2 lbs.
Electrical Data MODEL VOLTS UP26-116F & BF 23 0 NOTES: All dimensions are in inches. Subject to change without notice.
x
AMPS 1. 75
WAT T S 385
HP 1/ 6
CAP A CI T O R 2.5µF/380V
”F” dimension is the flange bolt centerline to centerl ine.
L-UP-T L-UP-TL-0 L-017 17 01/01 /01 PRINTED IN USA
1-9 19
1-10
Series UP 50-75F
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
FE ET
VOLT
PHASE
COMMENTS
Mounting Positions
Technical Data FLOW RANGE: 0 to 45 U.S. GPM HEAD RANGE: 0 to 27 Feet MOTOR: 2 Pole, Single Phase MINIMUM FLUID TEMPERATURE: 32°F (0°C) MAXIMUM FLUID TEMPERATURE: 230°F (110° (11 0°C) Ambi Ambien entt Air Air Temp Temp.. 95° 95°F (35 (35° °C) 130° 130°F (55° (55°C) 140° 140°F* (60 (60° °C) 160° 160°F (71° (71°C) 175° 175°F (79° (79°C) Maximum Maximum Water Water Temp. 230°F (110°C) 220°F (104°C) 210°F (99°C) 190°F (88°C) 175°F (79°C) ®
MAXIMUM WORKING PRESSURE: 145 145 PSI PSI MINIMUM REQUIRED INLET PRESSURE :
Recommended
230° 230°F (11 (110° 0°C) 190° 190°F (88° (88°C) 140° 140°F* (60° (60°C) 36 Ft. Ft. (1.1 (1.10m 0m)) 9.0 9.0 Ft. Ft. (2.8 (2.8m) m) 3.0 3.0 Ft. Ft. (0.9 (0.9m) m) 15.6 psi 4.0 psi 1.3 psi
DO NOT Mount Motor Shaft in Vertical Position
Optional
FOR INDOOR USE ONLY
Materials of Construction
Performance Curves
Inlet Inlet Cone, Cone, Beari Bearing ng Plate, Plate, Bearing Bearing Reta Retainer iners s Rotor Can, Rotor Cladding, Shaft Retainer, Impeller
UP50-75F 60Hz
Stator Housing Shaf Shaft, t, Uppe Upperr and and Lowe Lowerr Radi Radial al Bear Bearin ings gs Thrust Bearing Pump Housing (volute) O-Ring and Gaskets Terminal Box
Stainless Stainless Steel Steel PES Composite (30% Glass Filled) Aluminum Alum Alumin inum um Oxid Oxide e Ceramic Metal Impregnated Carbon Cast Iron EP (Ethylene Propylene Rubber) Noryl®
Note: Noryl is a registered trademark of General Electric Company
Electrical Data Mo d el
Dimensions and Weight M O DE L A UP 50 50 --7 7 5F 5F 8 1 / 2
B 7 1 / 2
C 51 / 16 16
D 4 7 / 8
E 3 1 / 2
F 41 / 16 16
V ol ts
Amps
Watts
HP
Capacitor
UP50-75F
115
2. 15
215
1
/ 6
10µF/180V
UP50-75F
230
1. 07
220
1
2.5µF/380V
/ 6
Shipping Wt. 15 1 / 2 lbs. NOTES: All dimensions are in inches. "F" dimension is the flange bolt centerline to centerline. L-UP-TL-015 12/00 PRINTED IN USA
1-11
1-12
Series UP BUC5 & BUC7
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps with Integral Check Valve and Bronze Union Sweat Fittings
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
FE ET
VOLT
PHASE
Technical Data FLOW RANGE: 0 – 16 U.S. GPM HEAD RANGE: 0 – 15 Feet MOTORS: 2 Pole, Single Phase
COMMENTS
Mounting Positions
MINIMUM FLUID TEMPERATURE: 36°F(2° (2 °C) MAXIMUM FLUID TEMPERATURE: 200° 200 °F (93° (9 3°C) C) MAXIMUMWORKING PRESSURE: 145 PSI
FOR OPEN SYSTEMS - 140°F 140°F (60°C) (60°C) Is the maximum maxi mum recommende d fluid temperature te mperature to avoid precipitation of calcium in water.
Recommended
Ambi Ambien entt Air Air Temp Temp.. 95° 95°F (35° (35°C) 130° 130°F (55 (55° °C) 140° 140°F (60° (60°C) 160° 160°F (71 (71° °C) 175° 175°F (79 (79° °C) Maximum Maximum Water Water Temp. Temp. 230°F (110°C) 220°F (104°C) 210°F (99°C) 190°F (88°C) 175°F (79°C) MINIMUM REQUIRED INLET PRESSURE: Temp Temper erat atur ure e 200° 200°F (93° 93°C) 140° 40°F (60° (60°C) Pressure 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 4.0 psi 1.3 psi
Optional
DO NOT Mount Motor Shaft in Vertical Position
FOR INDOOR USE ONLY
Nomenclature: B - Bronze, lead free pump housing
®
U - Union connection connection for check valve
C - Integral check valve 5 - 1/2” copper pipe, female sweat fittings 7 - 3/4” copper pipe, female sweat fittings
Materials of Construction
Performance Curves 1. 2. 3. 4. 5. 6.
) . T F ( D A E H
UP1 UP15-1 5-10BU BUC5 C5 UP1 UP15-1 5-10BU BUC7 C7 UP1 UP15-1 5-18BU BUC5 C5 UP1 UP15-1 5-18BU BUC7 C7 UP1 UP15-4 5-42BU BUC5 C5 UP1 UP15-4 5-42BU BUC7 C7 60 Hz
Inle Inlett C on one, Beari earing ng Plate late,, Beari earin ng R eta etain iner ers s Rotor Can, Rotor Cladding, Shaft Retainer, Check Valve Spring Stator Housing Shaft, Upper and Lower Radial Bearings
Stain tainle less ss Steel teel
Aluminum Aluminum Oxide Ceramic Metal Impregnated Carbon Lead Free Bronze (Alloy C875) Brass (UNS C36000) EP (Ethylene Propylene Rubber) PES Composite (30% Glass Filled) Noryl® POM (polyoxymethylene)
Thrust Bearing Pump Housing (volute) Tail Piece and Union Nut O-Ring and Gaskets Impeller Terminal Box Check Valve Housing, Valve and Torpedo
CAPACITY (U.S. GPM)
Dimensions and Weight M od el UP15BUC5 UP15BUC7
A B 6 1 / 2 5 1 / 4 7 3 / 4 5 1 / 4
C 4 4
D 3 3 / 16 16 3 3 / 4
E Con ne cti on Ship Wt. 3 1 / 4 Sweat 1 / 2” 7 1 / 4 lbs. 1 3 3 / 4 Sweat / 4” 8 lbs.
*NOTES:
All dimensions are in inches.
Union Gasket
Non Asbestos Fiber
Note: Noryl is a registered trademark of General Electric Company
Electrical Data M od el UP15-10BUC5 UP15-10BUC7 UP15-18BUC5 UP15-18BUC7 UP15-42BUC5 UP15-42BUC7 L-UP-TL-013 Rev. 01/01 PRINTED IN USA
V ol ts 11 5 11 5 115 115 115 115
Amp s 0. 55 0. 55 0. 74 0. 74 0. 74 0. 74
Watts 60 60 85 85 85 85
HP 1/25 1/25 1/ 25 1/ 25 1/ 25 1/ 25
Capacitor 8µF/180V 8µF/180V 10µF/180V 10µF/180V 10µF/180V 10µF/180V
Grundfos Pumps Corporation 3131 N. Business Park Avenue • Fresno, CA 93727 PA • Fresno, CA Customer Service Centers: Allentown, PA (559) 292-80 292-8000 00 • Fax: (559) (559) 291-13 291-1357 57 Phone: (559) ISO9001 Oakville, le, Ontari Ontario • Mexico: Apodac Apodaca, a, N.L. N.L. Canada: Oakvil REGISTERED Visit our website at www.us.grundfos.com
1-13
1-14
Series UP Timer & Line Cord Models
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
F E ET
VOLT
PHASE
COMMENTS
Mounting Positions
Technical Data FLOW RANGE: 0 to 17 U.S. GPM HEAD RANGE: 0 to 16 Feet MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 150°F 150°F (66°C), (66°C), Maximum Maximu m design temperature. temperature . MIN. FLUID TEMPERATURE for UP15: 36°F (2°C) TIMER: 24 hours 3 positions (ON/TIMER/OFF) 15 minute interval. LINE CORD: Six-Foot 18-3 with 5-15P grounded plug. MAXIMUM WORKING PRESSURE: 145 PSI MINIMUM REQUIRED INLET PRESSURE: At 150°F 150°F (66°C), (66°C), 3.0 Ft. (0.9m) (0.9 m) 1.3 PSI. P SI.
Recommended
DO NOT Mount Motor Shaft in Vertical Position
Optional
FOR INDOOR USE ONLY
Dimensions, and Weights UP15-10B5 & B7, UP15-18B5 & B7, UP15-42B5 & B7
Timer & Line Cord
UP15-10BUC5 UP15-10BUC7
UP15-18SU
6 . 1
C 5 2 . 4
7 7 . 3
5 2 . 1
5 9 . 2
5 2 4 .
5 8 . 2
6’ F
TIMER & LINE CORD MODELS UP15-10B5/LC & TLC
F
F
Shipping Wt. (Lbs.)
A 5
B 6 3 / 16 16
C 5 1 / 2
D 4
E 3 1 / 2
F 4
Connection Type and Size Sweat – 1 / 2 "
UP15-10B7/ LC & TLC
6 3 / 8
6 5 / 8
5 1 / 2
3 13 / 16 16
3 1 / 4
4
Sweat – 3 / 4 "
7.2
UP15-18B5/LC & TLC
5
3 16 16
6 /
5 /
3 /
1 4
3 /
4
Sweat – / "
6.5
UP15-18B7/LC & TLC
3
6 / 8
5
6 / 8
1
5 / 2
13
3 / 16 16
1
3 / 4
4
Sweat – / 4 "
7.2
UP15-42B5/LC & TLC
5
6 3 / 16 16
5 1 / 2
3 1 / 2
3 1 / 4
4
Sweat – 1 / 2 "
6.5
UP15-42B7/LC & TLC
6 /
5 8
6 /
3 /
4
3 4
Sweat – / "
7.2
1 2
1 2
1 2 3
6.5
5 /
3 /
UP15-10BUC5/LC & TLC
1
6 / 2
3
6 / 4
1
5 / 2
3
3 / 16 16
1
3 / 4
4
Sweat / 2”
7.7
UP15-10BUC7/LC & TLC
7 3 / 4
6 3 / 4
5 1 / 2
3 3 / 4
3 1 / 4
4
Sweat 3 / 4”
8.5
UP15-18SU/LC & TLC
5 / 8
6 / 16 16
5 / 2
3 / 16 16
3 / 4
4
Union – 1 / 4" NPSM
5.5
NOTES: All dimensions are in inches.
3 8
7
4
1 2
1
13 16 16
7
1 4
1
1
1
1-15
Performance
Stainless Steel or Bronze Construction - Flange, Union, or Sweat Mount
20
1. 2. 3. 4. 5. 6. 7. 8. 9.
15
) . T F ( D 10 A E H
UP15-1 UP15 -10B 0B5 5 UP15 UP 15-1 -10B 0B7 7 UP15 UP 15-1 -10B 0BUC UC5 5 UP15 UP 15-1 -10B 0BUC UC7 7 UP15 UP 15-1 -18S 8SU U UP15 UP 15-1 -18B 8B7 7 UP15 UP 15-1 -18B 8B5 5 UP15 UP 15-4 -42B 2B5 5 UP15 UP 15-4 -42B 2B7 7
Note: Performance shown is for 115V models. 230V models will vary slightly.
5
7
5
8
9
6
3 1 4 2 0 0
5
10
15
20
CAPACITY (U.S. GPM)
Electrical Data M OD E L UP15-10B5 & B7 UP15-18SU & B5 UP15-18B7
VOLTS 115 115
AMPS WAT TS . 55 60 . 74 85
11 5
. 74
85
HP 1 / 25 25 1 / 25 25
C AP AC I T OR 8µF/180V 10µF/180V
/ 25 25
10µF/180V
1
M O DE L UP15-42B5
VOLTS 115
AMPS WATT S . 74 85
UP15-42B7
115
. 74
85
UP15-10BUC5/7
115
0. 55
60
HP 1 / 25 25
CA P ACI T O R 10µF /180V
/ 25 25
10µF/180V
1/ 2 5
8 µ F / 1 8 0V
1
Materials of Construction
1-16
DESCRIPTION
MATERIAL
DESCRIPTION
MATERIAL
Inlet Cone, Bearing Bearing Plate, Plate, Bearing Bearing Retainers, Retainers, Rotor Rotor Can, Rotor Cladding, Shaft Retainer. Pump Housing (Volute) on UP15-18SU/SF
304 Stainles Stainless s Steel
O'Ring & Gaskets
EP (Ethylene Propylene Rubber)
Pump Pump Hous Housin ing g (Vo (Volu lute te)) for for UP15 UP15-1 -10B 0B5 5 & B7, B7, UP15-18B5 & B7, UP15-42B5 & B7, UP15-10BUC5 & B7
Sili Silico cone ne Bron Bronze ze C875 C875
Volut olute e Ret Retai ain ner (SU (SU Mod Model el)) & Sta Stato torr Hou Housi sing ng
Aluminum
Impeller
Shaft, Upper & Lower Radial Bearings
Aluminum Oxide Ceramic
PES Composite (30% Glass Filled)
Thrust Bearing
Metal Impregnated Carbon
Terminal Box
® Noryl ®
L-UP L-UP-T -TLL-03 034 4 Rev. Rev. 8/00 8/00 PRINTED IN USA
Series UP Comfort
Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps
Submittal Data
60 Cycle
JOB or CUSTOMER: ENGINEER:
DATE:
APPROVED BY:
DATE:
ORDER NO:
DATE:
SPECIFICATION REF: QUANTITY
TAG NO.
MODEL NO.
GPM
FEET
VOLT
PHASE
Technical Data
COMMENTS
Nomenclature
FLOW RANGE: 0 – 3 U.S. GPM HEAD RANGE: 0 – 5.4 Feet MOTORS: Single Phase, 115V
MINIMUM FLUID TEMPERATURE: 36°F (2°C) MAXIMUM FLUID TEMPERATURE: 203°F (95°C) MAXIMUM WORKING PRESSURE: 145 PSI
N e w I t e m
N e w I t e m
CONTRACTOR: SUBMITTED BY:
N e w I t e m
B - Brass, lead free pump housing 5 - ½" Copper Pipe, Female sweat sweat fittings
N e w I t e m
N e w I t e m
N5 - ½" NPT - Female thread fitting U - Union connection, 1¼" NPSM with
FOR OPEN SYSTEMS - 140°F (60°C) Is the maximum recommended fluid temperature to avoid precipitation of calcium in water.
Isolation valve & check valve. A - Thermostat
Ambi Ambien entt Air Air Temp Temp.. 149° 149°F (65° (65°C) 169° 169°F (75° (75°C) Maximum Maximum Water Water Temp. Temp. 203°F (95°C) 176°F (80°C)
T - 24-hour timer LC - Line cord and plug
N e w I t e m
MINIMUM REQUIRED INLET PRESSURE:
Temp Temper erat atur ure e P r es sur e
203° 203°F (95° (95°C) 9 Ft. (2.8m) 4.0 psi
185° 185°F (85° (85°C) 1.6 Ft. (0.5m) 0.7 psi
N e w I t e m
Mounting Positions
MOTOR: A green light on the motor is on when power is supplied to the pump.
TIMER: 24-hour AM/PM, 20 minute interval. DO NOT
FOR INDOOR USE ONLY
Mount in this Position
Dimensions and Weights
N e w I t e m
N e w I t e m
UP 10-16B5/BN5 Mode l Type
L1
UP 10-16 B5/LC UP 10-16 B5/TLC UP 10-16 B5/ATLC UP 10-16 BN5/LC UP 10-16 BN5/TLC UP 10-16 BN5/ATLC UP 10-16 BU/LC UP 10-16 BU/TLC UP 10-16 BU/ATLC
3 1/8 3 1/8 3 1/8 3 1/8 3 1/8 3 1/8 4 1/3 4 1/3 4 1/3
L2 3 1/2 3 1/2 3 1/2 3 1/2
UP 10-16BU
H1
H2
H3
1 1 1 1 1 1 1 1 1
1/2
5 1/4 8 1/16 8 1/16
1/2 1/2 1/2
5 1/4 8 1/16 8 1/16
1/2 1/2 7/8 7/8 7/8
H4
5 1/4 8 1/16 8 1/16
B1
B2
Wt. Lbs
3 3 3 3 3 3 3 3 3
3 1/3 3 1/3 3 1/3 3 1/3 3 1/3 3 1/3 3 1/3 3 1/3 3 1/3
2.9 3.4 3.4 2.9 3. 4 3. 4 3. 4 3. 8 3. 8
Connection Sweat 1/2" Sweat 1/2" Sweat 1/2" NPT 1/2" NPT 1/2" NPT 1/2" Union - 11/4" NPSM Union - 11/4" NPSM Union - 11/4" NPSM 1-17
N e w I t e m
N e w I t e m
Performance Comfort UP 10-16B/B5
Comfort UP 10-16BU
) . T F ( D A E H
) . T F ( D A E H
CAPACITY (US GPM)
CAPACITY (US GPM)
Electrical Data 1 X 115V P1 [W] 25
11/1 [A] 0. 23
Electrical connection The pump is fitted with 5 foot cord & 115V plug. Motor protection Impedance-protected. No external motor protection required.
Product Range
Thermostat: The built-in thermostat can be set to stop the pump at a preset liqui d temperature. The setting range is 95-15 0°F. The thermostat function can be interrupted by turning the thermostat to the position . The factory s etting of the th e thermostat i s: 95°F 95°F (35°C) (35°C)
UP 10-16 B5/LC UP 10-16 B5/TLC UP 10-16 B5/ATLC UP 10-16 BN5/LC UP 10-16 BN5/TLC UP 10-16 BN5/ATLC UP 10-16 BU/LC UP 10-16 BU/TLC UP 10-16 BU/ATLC
Materials of Construction DESCRIPTION Stator housing Spherical separator Rotor can complete Rotor, impeller Pump housing Isolation Valve
L-UP-TL-040 Rev. 03/01 PRINTED IN USA
1-18
MATERIAL Aluminium Stainless steel Stainless steel/tungsten carbide Stainless steel, EPDM, PPO, PFTE, graphite Brass MS 58 PPO
DESCRIPTION Terminal box cover, Motor Cover Screw Light Cable, Cable Relief Insulating cover Orings Check Valve
MATERIAL PA66/6 Stainless steel Lexan PVC EPP 55 EPDM POM