Rotor Seal Tubing assemlby for 2.5 mL syring Syringe, concentric, 100 uL Syringe, concentric, 250 uL Syringe, concentric, 500 uL Plunger, replacement, concentric, 100 uL Plunger, replacement, cencnetric, 250 uL Plunger, replacement, concentric, 500 uL Syringe, standard, 2500 μL (with needle tubing extension)
Vials and Bottles 60053-62017 A4954-010 00301-07527
Vial kit, 1.8 mL w/250 uL insert, 100 per pack Vial kit, 2 mL, 100 count, includes caps and septa (2 each) Reservoir vials, 16 mL
Maintenance Parts 60357-60017 A3692-010 60053-20031 F1100-020 F1100-010 00110-03-00013 00109-99-00021
Needle Assembly Syringe Valve Assembly Needle Port Syringe, concentric, 250 uL Syringe, concentric, 100 uL Injector Valve Rotor seal
Service Parts F1075-010 F9050-010 F9090-010 60357-63002 F9045-010 60053-60049 F9040-010 F9020-010 4004-0062
Arm Assembly Oven Sensor assembly Tray Sensor assembly Door LED Cable Arm Motor PCB CPU PCB Interconnect PCB Temperature Control PCB Main Power Supply
76472353.xls.ms_office
Back to Main
Accela Autosampler
3
Quantity 1 1 1 1 1 1 2 4 1
transfer tube between needle port and injeciton valve
also includes these parts for the Accela Autosampler 00109-99-00021 SEAL, ROTOR, INJ VALVE, ACCELA A/S 00109-99-00022 SEAL, ISO, INJ VALVE, ACCELA A/S, RoHS 60357-60017 ASSY, NEEDLE, INERT, ACCELA 60053-60014 ASSY, TRANSFER TUBE, VALCO C2 6 PORT VALVE F1123-020 PLUNGER, REPLACEMENT, 250UL DUAL SYRINGE 00301-01910
HAZ MAT LEAD SCREW GREASE,SILICON/TEFLON
A4954-010
SCREW-TOP VIAL KIT, 100/PK
00101-07-00001
NUT, COMP, LONG, RHEODYNE,1/16",10-32,
00109-99-00026
LOOP, SAMPLE, 25 uL, UHP INJ VLV, RoHS
Fluidic parts 00109-99-00019
High pressure filter, complete assemlby
76472353.xls.ms_office
Accela Pump
6
Quantity 4 4 1 2 2 2 2 4 2 1 1 4
replacement frit for inline filter between pump and AS
1 1 1 1 1 1 2 4 1
between pump and AS
76472353.xls.ms_office
Accela Pump
7
AS2000 (GC Autosampler) Part Number 36500525 36502019 24070010 38606031 24070005 38606040 24074041 38606074 28215011 28214018
76472353.xls.ms_office
Back to Main
Description Syringe 10 ul, 51 mm length fixed needle Syringe 10 ul, 80 mm length fixed needle 1.2 ml crimp top vial, 8mm finish, for 90 position tray Aluminum cap, 8mm with Teflon faced septum 2.5 ml crimp top vial, 11mm finish, for 90 position tray Aluminum cap, 11mm with Teflon faced septum 2 ml screw thread vial, 8mm finish, for 90 position tray Screw cap, 8mm Fuse, slow-blow, 800ma, 5x20 mm (for 230vac) Fuse, slow-blow, 1.6 A, 5x20 mm (for 115vac)
AS2000 (GC Autosampler)
8
AS3000 (GC Autosampler) Part Number 33330942 33330944 36500525 36500505 36520060 36504045 24014021 38606092 24074003 38606040
Back to Main
Description Front door AI3000 Front door AS3000 SGE 10 ul syringe (Standard) 5ul,50 mm needle syringe for microvolume S/SL injector SGE 10 ul syringe (for Merlin Microseal valve) SGE 0.5ul syringe for nano-volume injections 2ml screw top vials,(requires screw top caps with septa P/N 38606092) Screw top caps 2ml,4ml and 300ul vials complete with septa 2 ml crimp top vials, 11mm finish,(requires 11mm aluminum caps and seals P/N 38606040) cap al 11mm teflon sept 100ea
Description Rotor seal rheodyne, Vespel seal, standard applications PEEK Rotor seal XYZ Arm assembly XYZ Arm drive belt Injector valve assembly, w/o loop, standard Inert Injector valve assembly, w/ol loop 10 pc S. Steel Rheodyne extra long ferrule/nut 10 pc PEEK Rheodyne extra long ferrrule/nut 20 µL Rheodyne sample loop Stainless steel 50 µL Rheodyne sample loop Stainless steel 100 µL Rheodyne sample loop Stainless steel 200 µL Rheodyne sample loop Stainless steel 500 µL Rheodyne sample loop Stainless steel 1 mL Rheodyne sample loop Stainless steel Sample needle module, standard Sample needle module, inert 5 mL syringe 2.5mL syringe (Prep syringe) 1 mL screw-tip syringe 500 µL screw-tip syringe 250 µL screw-tip syringe Syringe drive, bare, without valve or motor (service spare) 3-port valve motor 3-port syringe valve Cap and lines for 250 mL bottle 250 mL solvent bottle Syringe six port valve (Valve/mounting bracket/mounting hardware) 6-way solvent selector valve and 24VDC motor Clear (sample compartment) cover Sparger or flush solvent filter (Polyethylene) Standard maintenance kit Bio/Inert Maintenance kit
A4954-010
Vial Kit,screw top, 2 mL, 100 count
A4967-010
Vial Kit,screw top, 2 mL, Amber glass 100 count
PCBs A9755-010S A9855-010S A9740-020S A3938-010
CPU PCBA Heater/Cooler PCBA (Peltier PCBA) OPTION PCB
Back to Main
Extra Description
AS3500 only
AS3500 only
AS1000/3000/3500
AS3500 only includes caps and silicone and Teflon® septa includes caps and silicone and Teflon® septa
KEYPAD/ DISPLAY ASSEMBLY
76472353.xls.ms_office
AS3000 (HPLC Autosampler)
10
Back to Main
TraceDSQ Part Number 119701-60287S 96000-60087 119650-0426S 70001-20532S 119650-0235S 119650-0220S 119650-0230 119650-0428 119650-0414 119650-0426 119650-0416 119650-0418 119650-0423 119650-0420
Description FILAMENT ASSY ASSY HEATER,ION SOURCE,DSQ/POLQ LENS SPACER POLARIS Q ION VOLUME HOLDER,GC INSULATOR FILAMENT POLARIS Q EI ION VOLUME POLARIS Q CI ION VOLUME POLARISQ LENS CIRCLIP POLARIS Q LENS 1 ION SOURCE POLARIS Q LENS SPACER POLARIS Q LENS 2 ION SOURCE POLARIS Q LENS 3 ION SOURCE POLARIS Q Lens 3 for use with the Ion Bright lens LENS HOUSING POLARIS Q
Alt Description Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts
96000-20176 119650-0151
SPRING ION VOLUME LENS ASSY DSQ (entire lens assembly)
119650-0490
SPACER THERMAL DSQ
119650-0495 119800-0535 119800-0500
SPACER THERMAL DSQ LENS PREFILTER DSQ Pre-Filter
Ion Source Parts Ion Source Parts Spacer used without the Ion Bright or, Lens 4 option Spacer used with the Ion Bright or, Lens 4 option Ion Bright lens, or Lens 4
119246-0001
ASSY CAL GAS MODULE
A0950-01600
TRAP OXY./MOISTURE/HYDROCARBON with base
A0950-R1600
Replacement filter for A0950-01500 assembly
119265-0003 A0022-02401
REPLACMNT SEAL KIT INLET VALVE POLARIS Q MULTIPLIER,REPLACEMENT DETECH
76022-0001
ETP Detector and Leads Kit
A0022-14633
ETP detector Cathode only
76472353.xls.ms_office
Used in older DSQ's, it is conical. Multiplier on newer DSQ's, rectangular shape. This is a kit for the an upgrade from the older style Multiplier on newer DSQ's, retangular shape.
DSQ
11
LTQ-ETD Part Number
Description
VACUUM PARTS 00301-15101 00950-01116 00301-08301
OIL,MECH PUMP, INLAND 19 OIL RESVR & OIL, TPH240/260L DUCT AIR 1.0 ID FLEX BLUE
Description Cathode, electron multiplier Filament assembly for GCQ Plus and Polaris. Filament assembly for GCQ original source only. Lens, L1. short pins Lens, L2, short pins Lens, L3, short pins LENS 1, long pins with 90 degree bend LENS 2, long pins with 90 degree bend LENS 3, long pins with 90 degree bend PCB, Ion Source Block and heater assembly Ion volume holder (1 ea) EI ION VOLUME Ion Volume, CI Power Module, 110 V ac Power Module, 220 V ac Tip, transfer line, Vespel (1 ea) Transfer line assembly (TRACE GC 2000 only) Calibration compound chamber Rotary-vane pump, RV3, 115 / 220 V ac
PCB's 96000-61160 96000-61150
PCB, Main System SOURCE INTERCONNECT PCB
76472353.xls.ms_office
GCQ
Back to Main
Extra Description most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part. most commonly replaced multiplier assembly part.
17
HS2000 (GC Autosampler) Part Number 24074020 24006305 38603800 38603600 38609410 36503005 36503006 36503007 19005326 19005327 19005328 28216001 28214018
Back to Main
Description Crimp-top 10ml vial, 20 mm finish Crimp-top 20ml vial, 20 mm finish AL.cap, 20 mm, butyl rubber septum (low temp. application) AL.cap, 20 mm, butyl rubber-Teflon faced septum (<100C. application) AL.cap, 20 mm, silicon-Teflon faced septum (up to 150C) Gas tight syringe 1.0 ml capacity (without plunger) Gas tight syringe 2.5 ml capacity (without plunger) Gas tight syringe 5.0 ml capacity (without plunger) Gas tight syringe 1.0 ml capacity complete with plunger and adapter Gas tight syringe 2.5 ml capacity complete with plunger and adapter Gas tight syringe 5.0 ml capacity complete with plunger and adapter Fuse, slow-blow, 1 A, 5x20mm (for 230V main) Fuse, slow-blow, 1.6, 5x20mm (for 115V main)
76472353.xls.ms_office
HS2000 (GC Autosampler)
18
LCQ Advantage
Back to Main
Part Number
Finnigan Description
Description
VACUUM PARTS 00301-15101 00301-08301 00105-01525 97000-62010 00301-24168 00108-02655 EX00108-02644 00950-01116
OIL,MECH PUMP, INLAND 19 DUCT AIR 1.0 ID FLEX BLUE Ion gauge Ion gauge kit 1" REINIFORCED VACUUM HOSE Pump, Mech, 650L/M, E2M30 220V,CE PUMP,TURBO,TMH261-130,200L/S OIL RESVR 190/240/260 TURB
Mechanical vacuum pump oil Blue vac pump exhaust tubing ion gauge only includes o-ring and mounting hardware MS to rough pump tubing - order by the fo Edwards E2M30 Mechanical Pump - CE c exchange turbo with integrated controller f Oil Medium to replace turbo lubricant
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
TUBE, ION TRANSFER, 450 µm CAPILLARY HEATER, lower block. Normal replacement part TUBE LENS SKIMMER O-RING,0.30ID,D,X0.064W,KALREZ,CMPD;4079 TOOL, CAPILLARY REMOVAL
behind ion transfer tube Ion transfer tube removal tool
LCQ ADVANTAGE & DECA XP ORTHOGONAL ESI LCQ ADVANTAGE & DECA XP ORTHOGONAL APCI APPI UPGRADE FOR APCI SOURCE APCI/APPI COMBINATION PROBE NANOSPRAY, LCQ ADVANTAGE & DECA XP PLUS ADAPTER, NANOSPRAY NSI-2 SOURCE MOUNT KIT FOR LCQ XP API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES LCQ ADVANTAGE & DECA XP,CE/MS LCQ ADVANTAGE MSN UPGRADE FOR XCAL 1.3 LCQ DUO MSn UPGRADE
76472353.xls.ms_office
LCQ Advantage
Part of Embedded Computer Part of Embedded Computer
Part of Embedded Computer
fuse for the RF amplifier fuse for the RF amplifier
only the exchange board is available (4-20 fuse for the system control board
part of the Embedded Computer.
Fuse for 200 volt power supply Valve for sheath and Aux gases Complete internal computer for Advantage
20
t mpliant (add EX prefix for exchange pump) r LCQ Duo and LCQ Advantage (not MAX)
76472353.xls.ms_office
LCQ Advantage
21
lored.
ter
10)
and Max
76472353.xls.ms_office
LCQ Advantage
22
LCQ Advantage Max
Back to Main
Part Number
Finnigan Description
Alt Description
VACUUM PARTS 00301-15101 00301-08301 00105-01525 97000-62010 00301-24168 00108-02655 00108-01-00003
OIL,MECH PUMP, INLAND 19 DUCT AIR 1.0 ID FLEX BLUE Ion gauge Ion gauge kit 1" REINIFORCED VACUUM HOSE Pump, Mech, 650L/M, E2M30 220V,CE PUMP,TURBO,TMH261-250
Mechanical vacuum pump oil Blue vac pump exhaust tubing ion gauge only includes o-ring and mounting hardware MS to rough pump tubing - order by the foot Edwards E2M30 Mechanical Pump - CE compliant (add EX prefix for exchange pump) exchange turbo with integrated controller
Seal Insulator, Spray shield, Ion Max Fone, spray shield Assembly, Capillary Heater, Deca2 - Use "S" Assembly, Clower Block/Heater Deca2 Heater Cartridge Capillary Mount, Skimmer & Tube Lens, 0.060 offset Tube Lens Skimmer O-RING,0.30ID,D,X0.064W,KALREZ,CMPD;4079 O-ring, 0.30ID x 0.064,Vespel TUBING,TYGON PVC 1"x3/16"w Ion transfer tube
under the ion transfer tube cone replaces Kalrez o-ring behind the ion transfer tube. Has better temperature resistance. API draing tubing. 1" ID. Tygon ID: Has a ring about 3 mm from the orifice that is 1mm wide. It a darker gray than the rest of the tube.
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
Electron Multiplier Assembly Electron Multiplier Kit
Normal replacement sub-assembly The whole thing. Replace if parts are discolored.
Probes OPTON-20011 OPTON-20012 O PT ON-20031 O PT ON-20029 O PT ON-20050 OPTON-20051 OPTON-20052 OPTON-20053 OPTON-53003 O PT ON-30004
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI(ADVANT AGE ) W IT H SW IT CHING VALVE NANO SPRAY ADAPT OR AND CAMERA FO R IO NMAX ION MAX NANO -SPRAY SO URCE MO UNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW MET AL NEEDLE FO R API 2 PROBES
replaces 97033-60030
PCB ACQ DSP PCB ASSY,CONTROL DSP PCB AY,ADV.MAX ISA BKPLANE/EMB SUPPRT BD PCB AY WAVEFORM/DDS ISA BUS AY,CPU VIPER830, PROGRAMMED,ADV. MAX built in ethernet ports. So separate NIC required Ethernet, SMC part of the Embedded Computer. Not used on new Advantage Max AY, EMBEDDED COMPUTER BOX, ADV. MAX Complete internal computer for Advantage and Max
76472353.xls.ms_office
LCQ Advantage Max
24
LCQ Classic (retired Jan 2009)
Back to Main
Part Number
Finnigan Description
Extra Description
VACUUM PARTS 00301-15101 00950-01116 00301-08301 00108-02655 00108-02642 00105-01525 97000-62010 00301-24168
OIL,MECH PUMP, INLAND 19 OIL RESVR & OIL, TPH240/260L DUCT AIR 1.0 ID FLEX BLUE Pump, Mech, 650L/M, E2M30 220V,CE Pump, Turbo, TMH 260/130, 200LF Ion gauge Ion gauge kit 1" REINIFORCED VACUUM HOSE
Mechanical vacuum pump oil Turbo Pump lubricant Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE c Turbo Pump ion gauge only includes o-ring and mounting hardware MS to rough pump tubing - order by the fo
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
LCQCLASSIC On-axis ESI Probe LCQCLASSIC Off-axis ESI Probe LCQCLASSIC APCI Probe API-1 Metal Needle Kit
Heated capillary cover
Serial interface pcb CUP Netwrok Interface Card (NIC) part of the E part of the Embedded Computer part of the Embedded Computer Motherboard for the embedded computer
Waveform DDS - part of the Embedded co big board under the right side panel Valve for sheath and Aux gases
Normal replacement sub-assembly The whole thing. Replace if parts are disc
10Base2, BNC type cable PCB,ASSY,10/100 NIC,PCI,3C905BCOMBO
Note: With the retirement of the LCQ (1 Jan 2009), LCQ Duo (1 July 2009), and LCQ Deca (1 July 2009), there are no heated c In regard to part availability, MASCOM (Bremen, Germany) is your best replacement source. 76472353.xls.ms_office
LCQ Classic
26
LCQ Classic (retired Jan 2009)
Back to Main
Per the MASCOM website (http://www.mascom-bremen.de/html/en/1/gid/__Online+Shop901090107901073901073190/c Alternatively, SIS (New Jersey) usually carry these parts. Please use the following URL for part availability. http://www.sisweb.com/search.htm?query=9700098002
76472353.xls.ms_office
LCQ Classic
27
mpliant (add EX prefix for exchange pump)
t
out of stock see note below out of stock see note below
76472353.xls.ms_office
LCQ Classic
28
bedded Computer
mputer
lored.
pillaries remaining in the Thermo Fisher Scientific stock.
OIL,MECH PUMP, INLAND 19 OIL RESVR & OIL, TPH240/260L DUCT AIR 1.0 ID FLEX BLUE FORELINES UNION HOSE CLAMP PUMP FITTING ADAPTOR CENTERING RING KF20/25 VACUUM HARDWARE CLAMP 1" REINIFORCED VACUUM HOSE Ion gauge Ion gauge kit Pump, Mech, 650L/M, E2M30 220V,CE
Mechanical vacuum pump oil Turbo Pump lubricant Blue vac pump exhaust tubing Tee connector fits the 1" ID reinforced tubing adapts hose end to the centering ring seal clamps the fitting adaptor MS to rough pump tubing - order by the foot ion gauge only includes o-ring and mounting hardware Edwards E2M30 Mechanical Pump - CE co
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
Acquisition DSP Control DSP CPU PCB, Analyzer Auxiliary PCB, Analyzer Top Cover PCB, DC Ring Filter PCB, Divert / Inject Valve PCB, Front Panel PCB, I/O Panel PCB, Low Pass Filter PCB, RF Voltage Amplifier PCB, RF Voltage Control PCB, Syringe Pump PCB, System Control PCB, Vent Delay PCB, Waveform Amplifier PCB,Ethernet, SMC Waveform DDS
part of the Embedded Computer part of the Embedded Computer part of the Embedded Computer
part of the Embedded Computer part of the Embedded Computer
00110-20014
VALVE AY,DUAL MNF.CNTL.W/PCB
Valve for sheath and Aux gases
Detector 96000-60036 96000-62019
Electron Multiplier Assembly Electron Multiplier Kit
Normal replacement sub-assembly The whole thing. Replace if parts are discol
API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
70005-62012 Kit, Heated Capillary, API2 2 EA $850 contains 70005-98041 HEATED CAPILLARY 1 EA 00107-10059 O-ring, 0.299" ID, 0.103" thick, Kalrez 1 Heated capillary o-ring (3 per year) 97000-20256 SLEEVE,API CAPILLARY 1 EA Heated Capillary Sleeve 70005-20224 Heated Capillary Mount Bushing 97000-20199 MOUNT,TUBE LENS & SKIMMER 2 EA 97000-20200 TUBE LENS 1 EA 97000-20201 SKIMMER 1 EA 97000-20281 BUSHINBG,CAPILLARY MOUNT 2 EA 00106-20005 TUBE,HYPODERMIC 26ga x10"L 304S 3 EA Heated Capillary Reamer 00107-10058 O-RING,3.737ID x .103THK,VITON 1 EA 70005-60077 ASSY,API CAPILLARY SEAL Heated capillary cover $90 Note: With the retirement of the LCQ (1 Jan 2009), LCQ Duo (1 July 2009), and LCQ Deca (1 July 2009), there are no heated c In regard to part availability, MASCOM (Bremen, Germany) is your best replacement source. Per the MASCOM website (http://www.mascom-bremen.de/html/en/1/gid/__Online+Shop901090107901073901073190/c Alternatively, SIS (New Jersey) usually carry these parts. Please use the following URL for part availability. http://www.sisweb.com/search.htm?query=9700098002
76472353.xls.ms_office
LCQ Deca
33
pliant (add EX prefix for exchange pump)
not in stock. See note below.
76472353.xls.ms_office
LCQ Deca
34
red.
76472353.xls.ms_office
LCQ Deca
35
pillaries remaining in the Thermo Fisher Scientific stock.
ntent.html)
76472353.xls.ms_office
LCQ Deca
36
LCQ DecaXP & plus
Back to Main
Part Number
Finnigan Description
Description
VACUUM PARTS 00301-15101 00301-08301 00108-02655 00301-24168
OIL,MECH PUMP, INLAND 19 DUCT AIR 1.0 ID FLEX BLUE Pump, Mech, 650L/M, E2M30 220V,CE 1" REINIFORCED VACUUM HOSE
Mechanical vacuum pump oil Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE MS to rough pump tubing - order by the f
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
LCQ ADVANTAGE & DECA XP ORTHOGONAL ESI LCQ ADVANTAGE & DECA XP ORTHOGONAL APCI APPI UPGRADE FOR APCI SOURCE APCI/APPI COMBINATION PROBE NANOSPRAY, LCQ ADVANTAGE & DECA XP PLUS ADAPTER, NANOSPRAY DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE NSI 2 UPGRADE FOR NSI XP SOURCE NSI-2 SOURCE MOUNT KIT FOR LCQ XP API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LCQ DecaXP & plus
38
ompliant (add EX prefix for exchange pump) ot
76472353.xls.ms_office
LCQ DecaXP & plus
39
es 97144-60260
er
olored.
76472353.xls.ms_office
LCQ DecaXP & plus
40
LCQ DecaXP Max
Back to Main
Part Number
Finnigan Description
Description
VACUUM PARTS 00301-15101 00301-08301 00108-02655 00301-24168
OIL,MECH PUMP, INLAND 19 DUCT AIR 1.0 ID FLEX BLUE Pump, Mech, 650L/M, E2M30 220V,CE 1" REINIFORCED VACUUM HOSE
Mechanical vacuum pump oil Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE MS to rough pump tubing - order by the f
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE NANOSPRAY AD ADAPTOR AN AND CA CAMERA FO FOR IO IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW F FL LOW ME METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LCQ DecaXP Max
43
ompliant (add EX prefix for exchange pump) ot
sfer tube. Has better temperature tem perature resistance.
76472353.xls.ms_office
LCQ DecaXP Max
44
IC integrated onto the CPU
olored.
76472353.xls.ms_office
LCQ DecaXP Max
45
76472353.xls.ms_office
LCQ DecaXP Max
46
LCQ Duo (retired Jul 2009)
Back to Main
Part Number
Finnigan Description
Extra Description
VACUUM PARTS 00301-15101 00950-01116 00301-08301 00108-02655 00301-24168 EX00108-02644 00950-01116
OIL,MECH PUMP, INLAND 19 OIL RESVR & OIL, TPH240/260L DUCT AIR 1.0 ID FLEX BLUE Pump, Mech, 650L/M, E2M30 220V,CE 1" REINIFORCED VACUUM HOSE PUMP,TURBO,TMH261-130,200L/S OIL RESVR 190/240/260 TURB
Mechanical vacuum pump oil Turbo Pump lubricant Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE compliant (add EX prefix for exchange pump) MS to rough pump tubing - order by the foot exchange turbo with integrated controller for LCQ Duo and LCQ Advantage (not MAX) Oil Medium to replace turbo lubricant
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
PCB AY FRONT PANEL PCB AY SYRINGE PUMP PCB ASSY I/O PANEL LCQ DECA PCB AY WAVEFORM/DDS ISA BUS PCB, RS 485/232 converter PCB, System Control PCB, ISA, Computer Support PCB, Syringe Pump Control PCB, I/O Panel PCB ASSY TOP COVER ELECT/OCT PCB, Switched Balun PCB, Front Panel PCB, Divert/Inject Valve PCB, Service Relay PCB, Waveform DDS
Detector 96000-60036 96000-62019
Electron Multiplier Assembly Electron Multiplier Kit
LCQDUO or DECA On-axis ESI Probe LCQDUO or DECA Off-axis ESI Probe LCQDUO APCI Probe API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES LCQ DUO MSn UPGRADE
Power Supplies 97134-60008 97134-60009 97033-60023 Rev E
Power supply +5, +/-15, +24 Volt DC Power supply +36, -28 Volt DC Power supply +48, +24 Volt DC
Back to Main
Part of embedded computer use Exxxx for the exchange board Part of embedded computer
Part of embedded computer
Normal replacement sub-assembly The whole thing. Replace if parts are discolored.
10Base2, BNC type cable PCB,ASSY,10/100 NIC,PCI,3C905BCOMBO
Note: With the retirement of the LCQ (1 Jan 2009), LCQ Duo (1 July 2009), and LCQ Deca (1 July 2009), there are no heated capillaries remaining in the Thermo Fisher Scientific stock. In regard to part availability, MASCOM (Bremen, Germany) is your best replacement source. Per the MASCOM website (http://www.mascom-bremen.de/html/en/1/gid/__Online+Shop901090107901073901073190/content.html) Alternatively, SIS (New Jersey) usually carry these parts. Please use the following URL for part availability. http://www.sisweb.com/search.htm?query=9700098002
ESI sample tube ESI needle seal ESI needle for fused silica sample tube for fused silica transfer tube HPLC tube nut (holds the ferrules 0010118114 and 00101-18120)
1 gram for calibration 1 mL of 1 mg/mL for calibration 20 mg for calibration 1 gram for sensitivity test
Digital PCB Analog PCB RF detector RF Coil LPF PCB Distribution PCB 300/150 Power supply Power Supply, +60v, +5v, +/-15v Dynode/Multiplier Power Supply AC Power module
Fleet and LXQ Fleet and LXQ Fleet and LXQ Fleet and LXQ Fleet and LXQ Fleet and LXQ None- PS on Analog PCB PS1 Fleet and LXQ Fleet and LXQ
Source PCB- use "S" Interlock PCB Digital PCB Distribution PCB Analog PCB Top Cover PCB I/O PCB Front Panel PCB Divert/Inject Valve PCB RF Amplifier PCB Electrometer PCB ASSY PCB,RF DETECTOR,DUAL - USE S Power Supply, +/-300v, +/-150v Power Supply, +60v, +5v, +/-15v Power Supply, +36v, +/-24v, +28v ASSY,8KV POWER SUPPLY W/FRAME Power Supply, 15kV Dynode and EM
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LTQ
56
ube. Has better temperature resistance.
liant (add EX prefix for exchange pump)
recommended replacement
e
76472353.xls.ms_office
LTQ
57
76472353.xls.ms_office
LTQ
58
Back to Main
LTQ XL Part Number
Description
Further Description
API STACK PARTS 97055-20198 00107-12750 97055-20442 97055-20253 97055-20251 00301-22922 97055-20035
Ion Transfer Capillary, 550 micron O-ring, 0.30ID x 0.064, Kalrez, CMPD 4079 O-ring, 0.30ID x 0.064,Vespel Skimmer Tube Lens TUBING,TYGON PVC 1"x3/16"w API source sweep cone
Ion transfer tube O-ring behind the ion transfer tube replaces Kalrez o-ring behind the ion transfer
OIL,MECH PUMP, INLAND 19 Mechanical vacuum pump oil Turbomolecular pump insert (Leybold TW 400/300/ Exchange turbo pump core DUCT AIR 1.0 ID FLEX BLUE Blue vac pump exhaust tubing Pump, Mech, 650L/M, E2M30 220V,CE Edwards E2M30 Mechanical Pump - CE com Pump hardware centering ring mounts to top of pump Vacuum hardware clamp KF-20/25 mounts to top of pump Hose clamp, band clamps hose to adapter Adapter, pump roughing line adapts tubing to pump PVC reinforced vacuum hose, 1.5-in. ID 3 port manifold, 1.5" external Y for connecting 2 pump lines Adapter, 1.5" adapts tubing to back of LTQ Swing clamp, NW 32/40, mounts to back of LTQ Centering ring, NW40, 41 mm ID mounts to back of LTQ Mist filter (a.k.a. "demister") Drain oil return kit Tool, extraction, minifit
Detection system 96000-60036 00022-02400
Electron multiplier assembly Electron multiplier cathode insert
ASSY,PCB, POWER DISTRIBUTION LTQ XL only ASM, PCB, POWER DISTRIBUTION,LTQ2 LTQ XL only ASSY,PCB,ANALOG w/XY-WFM LTQ XL only ASSY,PCB,ANALOG,NOVA LTQ XL only ASSY,PCB,ADVANCE TOP COVER LTQ XL only ASSY PCB,RF DETECTOR,DUAL - USE S also available as exchange Power Supply, +/-300v, +/-150v PS3 Power Supply, +60v, +5v, +/-15v PS1 Power Supply, +36v, +/-24v, +28v PS2 ASSY, 8KV PS, 100 MS, MOUNTED High voltage power supply for probes Power Supply, 15kV Dynode and EM Dual electron multiplier and conversion dynod PCB AY,SOURCE W/VALVES,ENDEAVOR - USE S
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LTQ XL
ESI sample tube
60
ube. Has better temperature resistance.
liant (add EX prefix for exchange pump)
recommended replacement
c e
76472353.xls.ms_office
LTQ XL
61
76472353.xls.ms_office
LTQ XL
62
LTQ Velo Part Number
Description
API STACK PARTS 70005-20606 00107-12750 97055-20442
Capillary 580 micron "V" type O-ring, 0.30ID x 0.064, Kalrez, CMPD 4079 O-ring, 0.30ID x 0.064,Vespel
ASSY,PCB, POW ER DISTRIBUTION ASM, PCB, POW ER DISTRIBUTION,LTQ2 ASSY,PCB,ANALOG w/XY-WFM ASSY,PCB,ANALOG,NOVA ASSY,PCB,ADVANCE TOP COVER ASSY PCB,RF DETECTOR,DUAL - USE S Power Supply, +/-300v, +/-150v Power Supply, +60v, +5v, +/-15v Power Supply, +36v, +/-24v, +28v ASSY, 8KV PS, 100 MS, MOUNTED Power Supply, 15kV Dynode and EM PCB AY,SOURCE W/VALVES,ENDEAVOR - USE
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR ION ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES HESI II PROBE
Back to Main Further Description
Ion transfer tube - Velos only O-ring behind the ion transfer tube replaces Kalrez o-ring behind the ion transfer tube. Has better temperature resistance.
API draing tubing. 1" ID. Tygon
Mechanical vacuum pump oil Exchange turbo pump core Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE compliant (add EX prefix for exchange pump) mounts to top of pump mounts to top of pump clamps hose to adapter adapts tubing to pump external Y for connecting 2 pump lines adapts tubing to back of LTQ mounts to back of LTQ mounts to back of LTQ
complete replacement
recommended replacement
LTQ XL only LTQ XL only LTQ XL only LTQ XL only LTQ XL only also available as exchange PS3 PS1 PS2 High voltage power supply for probes Dual electron multiplier and conversion dynode
For calibration and sensitivity testing 1 gram for calibration 1 mL of 1 mg/mL for calibration 20 mg for calibration 1 gram for sensitivity test
ESI Needle Seal for the ESI needle
ESI ground point union for tuning by infusion contains rotor seal and stator Infusion syringe Infusion syringe Injection syringe
ESI sample tube
High flow needle. This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. Low flow needle. This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. heater element
AX
Back to Main
LTQ-FT Part Number
Description
Further Description
VACUUM PARTS 00301-15101 EX00108-10022 00301-08301 691290 1195230 00108-02655
OIL,MECH PUMP, INLAND 19 Turbomolecular pump insert (Leybold TW 400/300/25) DUCT AIR 1.0 ID FLEX BLUE Hose IVS 25x4.5, 1.25m Helix Hose ID 45, L 2.4m Pump, Mech, 650L/M, E2M30 220V,CE
Mechanical vacuum pump oil Exchange turbo pump core Blue vac pump exhaust tubing Foreline vacuum hose Foreline vacuum hose Edwards E2M30 Mechanical Pump - CE c
ASSY PCB,RF DETECTOR,DUAL - USE S Power Supply, +/-300v, +/-150v Power Supply, +60v, +5v, +/-15v Power Supply, +36v, +/-24v, +28v Power Supply, 8KV Power Supply, 15kV Dynode and EM PCB AY,SOURCE W/VALVES,ENDEAVOR - USE S
also available as exchange PS3 PS1 PS2 High voltage power supply for probes Dual electron multiplier and conversion dy
ESI Probe Parts 00950-00990 00950-00952 00106-10499
Needle, D pnt 26 gauge, 2"L, 0.24D washer Seal STD needle 5000 series TUBING,FUSED,SI,.10IDx.190D
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LTQ-FT
68
mpliant (add EX prefix for exchange pump)
recommended replacement
fer tube. Has better temperature resistance.
ode
76472353.xls.ms_office
LTQ-FT
69
76472353.xls.ms_office
LTQ-FT
70
LTQ Orbitrap Part Number
Description
API STACK PARTS 97055-20198 00107-12750 97055-20442 97055-20253 97055-20251 00301-22922 97055-20035
Ion Transfer Capillary, 550 micron O-ring, 0.30ID x 0.064, Kalrez, CMPD 4079 O-ring, 0.30ID x 0.064,Vespel Skimmer Tube Lens TUBING,TYGON PVC 1"x3/16"w API source sweep cone
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONM ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
Power Supply, +/-300v, +/-150v Power Supply, +60v, +5v, +/-15v Power Supply, +36v, +/-24v, +28v Power Supply, 8KV Power Supply, 15kV Dynode and EM ASSY PCB,RF DETECTOR,DUAL - USE S
76472353.xls.ms_office
LTQ Orbitrap
72
Back to Main Further Description
Ion transfer tube O-ring behind the ion transfer tube replaces Kalrez o-ring behind the ion transfer tube. Has better temperature resistance.
API draing tubing. 1" ID. Tygon
10mL teflon bottle shipped with dry ice
MSCAL 5 from Sigma
10mL teflon bottle shipped with dry ice
MSCAL 6 from Sigma
For calibration and sensitivity testing 1 gram for calibration 1 mL of 1 mg/mL for calibration 20 mg for calibration 1 gram for sensitivity test
complete replacement
recommended replacement
Mechanical vacuum pump oil Exchange turbo pump core Blue vac pump exhaust tubing Foreline vacuum hose Edwards E2M30 Mechanical Pump - CE compliant (add EX prefix for exchange pump) Orbitrap Turbos 1, 2 and 4 (HCD area for HCD and ETD) built in controller Orbitrap Turbo 3 built in controller new ETD turbo includes controller replaces Edwards EXT70H
ESI ground point union for tuning by infusion contains rotor seal and stator Infusion syringe Infusion syringe Injection syringe
ESI sample tube
76472353.xls.ms_office
LTQ Orbitrap
73
Back to Main
AX
Thermoflex 900 chiller Exchange chiller available as EX101101010000023 Thermoflex 900 chiller M-33 chiller replacement pump head for TF 900 chiller recommend replacing the standard 100 micron filter bag flow sensor may be clogged by graphite particulate from the chiller pum p
also available as exchange also available as exchange also available as exchange also available as exchange
also available as exchange
PS3 PS1 PS2 High voltage power supply for probes Dual electron multiplier and conversion dynode also available as exchange
76472353.xls.ms_office
LTQ Orbitrap
74
LTQ Orbitrap Vel
Part Number
Description
API STACK PARTS 70005-20606 Capillary 580 micron "V" type 00107-12750 O-ring, 0.30ID x 0.064, Kalrez, CMPD 4079 97055-20442 O-ring, 0.30ID x 0.064,Vespel
ASSY,PCB, POWER DISTRIBUTION ASM, PCB, POWER DISTRIBUTION,LTQ2 ASSY,PCB,ANALOG w/XY-W FM ASSY,PCB,ANALOG,NOVA ASSY,PCB,ADVANCE TOP COVER ASSY PCB,RF DETECTOR,DUAL - USE S Power Supply, +/-300v, +/-150v Power Supply, +60v, +5v, +/-15v Power Supply, +36v, +/-24v, +28v ASSY, 8KV PS, 100 MS, MOUNTED Power Supply, 15kV Dynode and EM
ESI Probe Parts 00950-00990 00950-00952 00106-10499
Needle, D pnt 26 gauge, 2"L, 0.24D washer Seal STD needle 5000 series TUBING,FUSED,SI,.10IDx.190D
HESI II Probe Parts 70005-60155 Needle insert, 32 gauge, HESI II 70005-60180 Needle insert, 34 gauge, HESI II 70005-60157 Heater, HESI II Probes OPTON-20011 OPTON-20012 OPTON-20026 OPTON-30021 OPTON-20029 OPTON-20050 OPTON-20051 OPTON-20052 OPTON-20053 OPTON-53003 OPTON-30004 OPTON-20037
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES HESI II PROBE
s
Back to Main
Further Description
Ion transfer tube - Velos only O-ring behind the ion transfer tube replaces Kalrez o-ring behind the ion transfer tube. Has better temperature resistance.
API draing tubing. 1" ID. Tygon
Mechanical vacuum pump oil Exchange LTQ Velos turbo pump core Blue vac pump exhaust tubing Edwards E2M30 Mechanical Pump - CE compliant (add EX prefix for exchange pump) mounts to top of pump mounts to top of pump clamps hose to adapter adapts tubing to pump external Y for connecting 2 pump lines adapts tubing to back of LTQ mounts to back of LTQ mounts to back of LTQ
complete replacement
LTQ XL only LTQ XL only LTQ XL only LTQ XL only LTQ XL only also available as exchange PS3 PS1 PS2 High voltage power supply for probes Dual electron multiplier and conversion dynode
For calibration and sensitivity testing 1 gram for calibration 1 mL of 1 mg/mL for calibration 20 mg for calibration 1 gram for sensitivity test
ESI Needle Seal for the ESI needle
ESI ground point union for tuning by infusion contains rotor seal and stator Infusion syringe Infusion syringe Injection syringe
ESI sample tube
High flow needle. This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. Low flow needle. This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. heater element
Back to Main
LXQ Part Number
Description
Further Description
ESI Probe Parts 00950-00990 00950-00952 00106-10499
Needle, D pnt 26 gauge, 2"L, 0.24D washer Seal STD needle 5000 series TUBING,FUSED,SI,.10IDx.190D
ESI Needle Seal for the ESI needle ESI sample tube
API STACK PARTS 97055-20517 00107-12750 97055-20442 97055-20253 97055-20251 00301-22922
Ion Transfer Capillary, 550 micron O-ring, 0.30ID x 0.064, Kalrez, CMPD 4079 O-ring, 0.30ID x 0.064,Vespel Skimmer Tube Lens TUBING,TYGON PVC 1"x3/16"w
Ion transfer tube O-ring behind the ion transfer tube replaces Kalrez o-ring behind the ion transfer
Digital board Analog board RF detector board RF coil LPF board Distribution board Dynode/Multiplier power supply AC module PCB AY,SOURCE W/VALVES,ENDEAVOR - USE S
ESI PROBE, ION MAX SOURCE APCI PROBE FOR ION MAX APPI FOR ION MAX SOURCE MALDI ION SOURCE FOR LTQ NANOSPRAY ADAPTOR AND CAMERA FOR IONMAX ION MAX NANO-SPRAY SOURCE MOUNT KIT STATIC NANO-SPRAY PROBE DYNAMIC NANO-SPRAY PROBE PACKED TIP NANO-SPRAY PROBE API-2 METAL NEEDLE KIT LOW FLOW METAL NEEDLE FOR API 2 PROBES
76472353.xls.ms_office
LXQ
ESI ground point union for tuning by infusion contains rotor seal and stator Infusion syringe Infusion syringe Injection syringe
SAP Description SYRINGE,25ul,micro as SEAL,ROTOR,C2-1346 INJ. VALVE,micro as NEEDLE,,SAMPLE, F/S 2.4ul, micro as VALVE,SYRINGE,micro as NEEDLE,PREPUNC,AIR,micro as OPTP INTERRUPTOR, micro as STATOR FOR MICRO BIO VALVE, micro as INJECT MARKER CABLE, micro as STEPPER MOTOR 1.05A, micro as RUBBER FOOT KIT, 6, micro as STEPPER MOTOR 2.2A, micro as TUBE, 1/8" x 1/16", PTFE, micro as BUFFER TUBING, 50ul PEEK micro as TRANSPORT NUT, M5, micro as PACKAGE, SEAL RINGS, MS 10, micro as NEEDLE BODY, micro as WASTE OUTLET, micro as BELT,B-SQ025,25.0 X 1.2, micro as FAN,24V,micro as CABLE,PWR,EUROPE,micro as CABLE,POWER,USA,micro as KEYBOARD COVER, ASSY, micro as TRANSFORMER, 2x120/30,micro as BRIDGE RECTIFIER, micro as FILTER, LINE, micro as DO NOT USE NEEDLE HOLDER AY, micro as EPROM, MICRO AS, micro as SYRINGE SPINDLE REPLACE AY,micro as VIAL,WASH SOLVENT,CAPS, micro as STRETCHING BLOCK ASSY, micro as NEEDLE UNIT ASSY, micro as PULLEY ASSY, micro as TEMP SENSOR, ASSY, micro as MOTOR AY,SAMPLE NEEDLE, micro as VALVE ASSY, INJECT micro as PUMP ASSY, MEMBRANE, micro as SPINDLE ASSEMBLY, micro as VIAL STRIPPER ASSY, SPRK ONLY PULLEY,PLB,72MXL025, micro as PULLEY,PLA,18 MXL micro as PULLEY,18 MXL micro as BELT, 520 MXL,025, micro as BELT TYPE 1920 MXL 012, micro as BELT, 760 MXL 025, micro as BELT, 912 MXL, micro as VALVE, MICRO, BIO,INJ, micro as BOTTLE,WASH SOLVENT, 250mL, micro as MOTOR,12VDC WITH GEARBOX, micro as BRACKET, WASHBOTTLE, micro as GEARWHEEL, TRAY, micro as I/O PCB, micro as
FLEX PCB, micro as BACK PANEL CONNECT I/O PCB micro as NEEDLE UNIT PCB, micro as MULTILINK INTERFACE PCB, micro as IC,RAM,BATERY BACKUP MK 48Z58 micro as TRAY DRIVE MOTOR ASSEMBLY, micro as SYRINGE DISPENSER ASSBLY, micro as TRAY DRIVE PCB, micro as PELTIER PCB, micro as SYRINGE DISPENSER PCB, micro as VALVE PCB ISS/SSV, micro as PCB, CPU BUS, micro as PLATE HOLDER AY STD, micro as IC,RAM BATTERY BACK MK48T58 micro as NEEDLE WASH INSERT VALVE,5mmODx1.5mmID SEAL, ROTOR,VALCO,micro as PLATE HOLDER ASSY, COOLER, micro as PELTIER ASSY, micro as SHIP KIT,MICRO AS, micro as SHIP BOX INCL. INSERTS, micro as
00960-01-00010
Micro AS Parts and Accessories Kit Contains 48-vial adapter 1 Injection marker cable 1 2.4 µL biocompatible fused silica needle 1 5.0 µL biocompatible fused silica needle 1 0.25 in. female Luerlock fitting 1 3-stranded networking cable 2 Glass fuses, UL, ¼ in. × 1¼ in. 4 10 mL vials, 20 mm × 47 mm 4 Septa for vials 4 Caps for vials 1 Masterblock® U 96-well polypropylene plate 1 96-well polystyrene plate 1 Capmat for Masterblock 96-well plate 1 10 µL PEEK injection loop 1 100 µl Luerlock syringe 1.2 m Silicone tubing, ID 7.0 mm, OD 10.0 mm
FILAMENT ASSY ASSY HEATER,ION SOURCE,DSQ/POLQ LENS SPACER POLARIS Q ION VOLUME HOLDER,GC INSULATOR FILAMENT POLARIS Q EI ION VOLUME POLARIS Q CI ION VOLUME POLARISQ LENS CIRCLIP POLARIS Q LENS 1 ION SOURCE POLARIS Q LENS SPACER POLARIS Q LENS 2 ION SOURCE POLARIS Q LENS 3 ION SOURCE POLARIS Q LENS HOUSING POLARIS Q SPRING ION VOLUME SPACER, END CAP POLARIS Q ASSY CAL GAS MODULE POLARIS Q TRAP OXY./MOISTURE/HYDROCARBON with base Replacement filter for A0950-01500 assembly REPLACMNT SEAL KIT INLET VALVE POLARIS Q MULTIPLIER,REPLACEMENT DETECH
Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts Ion Source Parts
76472353.xls.ms_office
PolarisQ
92
P-series pumps Spectra System Pumps (P100/200/1000/1500/2000/4000) Part Number A3070-010 A4179-010 A2962-010 A4902-010 A3102-010 A4848-010 A2963-010 A3495-010 A3990-010 A3477-010S A3986-010S A3923-010S A3922-010S A3902-010S A4258-010 A4929-010 A4050-010
Description PISTON SEALS (PKG OF 10) STANDARD GOLD PISTON SEALS (PKG OF 4) STANDARD GOLD PISTON SEALS (PKG OF 1 ) STANDARD GOLD+A22 PISTON SEALS (PKG OF 4) BLACK PISTON 10 ml/min SAPPHIRE KEL F SEAL PISTON FLUSH SEAL (1) INLET CHECK VALVE TRANSDUCER CHECK VALVE INLET TUBE (P1000,1500) TO INLET CHECK VALVE INLET TUBE, GRADIENT BLOCK TO CHECK VALVE GRADIENT PROP. VALVE 2 WAY GRADIENT PROP. VALVE 4 WAY 2 WAY SOLVENT VALVE Teflon Solvent Filter Stainless Steel Solvent Filter STANDARD MAINTENANCE KIT
Extra Description
For P-200/2000 For P4000 For P1500
include complete bottle cap, tubing and solvent filter
Metal 6 port valve face plate of the injector model 7739 is now available 6/2004
Stator Needle Assembly Needle Port Waste Tube assembly
34 uL dead volume (before No Waste Option)
Transfer Tube 34 uL
17 uL dead volume (Used with No Waste Option; has a blue piece of tape around it indicating it is the 17uL) for Rheodyne valve Used with Valco injector valve
Transfer Tube 17 uL Transfer tube assembly 100ul Syringe complete concentric syringe 250ul Syringe 500ul Syringe 100ul Syringe Plunger 250ul Syringe Plunger 500ul Syringe Plunger 2500ul Syringe Kit Wiring harness Solvent Filter Bottle, 16 mL, includes cap, for sample preparation (4 each) Bottle, flush, 250 mL syringe valve Port, needle Drive, syringe Upgrade to Valco valve order 60053-62042 upgrade kit Rheodyne Valve Not Available anymore Valco C2 Valve, injector
PCBs
F9025-010
Back board that the CPU PCB plugs into when inserted
PCB, Backplane
76472353.xls.ms_office
Surveyor Autosampler
94
Surveyor Autosampler F9045-010
PCB, Arm Motor
F9015-020 60053-60031
PCB, CPU CPU PCB Spare Assy
F1001-010 F9030-010
Bracket, CPU Board PCB, Front Panel LED
F9040-010 F9020-010
Sensor PCBA for Arm Assembly Has been Changed from F9015-010. Does not include the CPU Board Bracket (metal plateform with door sensor) See 6005360031 and F1001-010 Includes F9015-020 and F1001-010 Metal plate that the CPU PCB attaches to. This also includes the Door sensor. Includes F1042-010 Y-axis cable (pink/ white)
includes caps and silicone and Teflon® septa includes caps and silicone and Teflon® septa includes: Lubricants (triflow and trigel), rotor seal, plunger for 250uL syringe, and peak injector port stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel stainless steel Standard seal Includes needle, tubing and fittings This is the replacement needle with fitting
complete concentric syringe
reservoir bottle
Back board that the CPU PCB plugs into when inserted Sensor PCBA for Arm Assembly Includes CPU board and bracket F1001-010 Metal plate that the CPU PCB attaches to. This also includes the Door sensor.
For PE High Pressure Seal, goes in the pump head For PE High Pressure Seal, goes on pump seal so it covers spring
White Rinse/Flush Seal Holder (SS) includes drain valve assy with knob
SS Holder Ring that Rinse Seal Holder Goes Into w/nuts & ferrules
Gold, High Pressure, Seal Graphite Impregnated Teflon High Pressure Seal that can be used in place of the Polyethylene (Gold) seal p/n 00950-30004. The GFP Seal is designed for Normal Phase Chromatography Solvents (I.E Seal, GFP (Graphite Impregnated Teflon), High Chloroform) and consistently high ACN mobile phases Pressure (always run 80% or higher). Teflon Solvent Filter Stainless Steel Solvent Filter Ethernet Cable
PCB Assy, Pump CPU, TF F/W PCB Assy, Gradient Controller PCB Assy, Pressure Sensor PCB Assy, Pump Driver PSB Assy, Home Position Sensor PCB Assy, Interconnect Converter / Ethernet, PCBA Assy (Communications Board) Power Supply board 24VDC/ 63 A output
mp before 08/2006
Back to Main
Extra Description Parts necessary for annual maintenance
White, flush/ backup, seals
For PE High Pressure Seal, goes in the pump pum p head For PE High Pressure Seal, goes on pump seal so it covers spring
White Rinse/Flush Seal Holder (SS) includes drain valve assy with knob
SS Holder Ring that Rinse Seal Holder Goes Into w/nuts & ferrules
Gold, High Pressure, Seal Graphite Impregnated Teflon High Pressure Seal that can be used in place of the Polyethylene Polyethylene (Gold) seal p/n 00950-30004. The GFP Seal is designed for Normal Phase Chromatography Solvents (I.E Chloroform) and consistently high ACN mobile phases (always run 80% or higher).
PCB Assy, Pump CPU, TF F/W PCB Assy, Gradient Controller PCB Assy, Pressure Sensor PCB Assy, Pump Driver PSB Assy, Home Position Sensor PCB Assy, Interconnect Converter / Ethernet, PCBA Assy (Communications Board) Power Supply board 24VDC/ 63 A output
p Plus After 08/2006
Back to Main
Extra Description Parts necessary for annual maintenance
White, flush/ backup, seals
White Rinse/Flush Seal Holder (SS) includes drain valve assy with knob
w/nuts & ferrules
Gold, High Pressure, Seal Graphite Impregnated Teflon High Pressure Seal that can be used in place of the Polyethylene (Gold) seal p/n 00950-30004. The GFP Seal is designed for Normal Phase Chromatography Solvents (I.E Chloroform) and consistently high ACN mobile phases (always run 80% or higher).
Pressure sensor set Coil Unit for Proportioning Valve Proportioning Valve (Sold individually) LDA ASSY (whole thing) Surveyor MS Pump Manual Pulse Dampener Teflon Solvent Filter Stainless Steel Solvent Filter Luer-Type Adaptor for syringe Seal Removal Tool
00950-01-00021 KIT, KIT, TUBING, No-Ox, SURVEYOR MS PUMP 00110-01-00007
VALVE, PROP, MS PUMP, + TYPE, 1/4-28 THRD
PCBs 60053-61001 60052-61001
Surveyor Vacuum PCB ASSY SCM Vacuum PCB ASSY
72011-61001
Degass Monitor & Serial PCB ASSY
76472353.xls.ms_office
Surveyor MS Pump& MS Pump Plus
107
Surveyor MS Pump & 70005-61090
Surge Absorber PCB ASSY
F9030-010 00950-01-00074
LED PCB ASSY CPU PCB
00950-01-00075
CPU PCB
76472353.xls.ms_office
Surveyor MS Pump& MS Pump Plus
108
S Pump Plus
Back to Main
Extra Description Requires Hexane and Silicone Includes 2 primary and secondary seals, 2 check valves, 2 pistons, 5 Teflon spacer seals, 2 large Teflon spacer piston holder seals, 1 peek outlet cartridge seal, and 1 seal removal tool Black (graphite impregnated Teflon); Requires 2 (one for each piston) Made of PEEK and goes between the outlet and the pressure transducer White (PTFE); Requires 2 (one for each piston) white (PTFE); Requires 2 (one for each piston holder to seal) white (PEEK) requires 5; one after/before each check valve and one before outlet cartridge
made of Ti / Ruby; requires 2 (one for each chamber) made of SS and require 2 (one for each piston) made of SS, requires 1, piece that connects the outlet check valve to the pressure transducer (looks like a upside down funnel) made of SS /Ruby requires 2 (AKA piston/seal holder) made of PTFE, requires 4 (one for each valve) made of SS, "A" shape, aligns/supports the piston made of SS and Ruby, aka piston holder, requires 2 made of Ti, requires 2 made of PEEK /TI, (AKA Pressure Transducer); part must be RGA'd (returned) back to Cindy Taylor in San Jose Made of SS /PEEK, requires 4 (one for each valve) Old style. Stopped late 2004. includes whole LDA previously 60053-97042
The inner wall is Teflon but the outer wall is the less permeable PVDF. This kit includes the flangeless fittings that seal the tubing to the proportioning valve. Introduced late 2004. Proportioning valve that accepts the flangeless fittings for the "No-Ox" tubing.
New style Teflon AF (500uL) degasser PCB Old Style Teflon (12mL) degasser PCB Full Assembly, Converter Board/ communications board 76472353.xls.ms_office
Surveyor MS Pump& MS Pump Plus
109
S Pump Plus
Back to Main
Power CPU from backplane board to back of Rheos Board the powers the Led lights on the front of the MS pump MS Pump with serial number < 68073 MS Pump with serial number > 68073 and MS pump Plus
76472353.xls.ms_office
Surveyor MS Pump& MS Pump Plus
110
Surveyor PDA Part Number 108052 803247 126078 126079 802259 A3538-010 A3638-010 60053-97034 703909 703903 EXF3000-010
803237-01 803265
Description Deuterium Lamp Assembly (pre-aligned) Tungsten-halogen (W ) Lamp Assembly (pre-aligned) Fuse, T3.15 A (5 x 20 mm) (for 100/115 V operation) Fuse, T1.6 A (5 x 20 mm) (for 230 V operation) Backpressure regulator 9 pin to RJ-45 adapter Cable 4-PIN RJ45 SURVEYOR LC PDA HARDWARE Manual WINDOW,COMBINER CELL CLAMP 10MM UV6000LP Bench Assembly exchange only Flowcell Assembly, with inlet/outlet tubing and fittings (5 cm Lightpipe) 10 mm flow cell Assembly (1 cm LightPipe)
2522-0285
FITTING FINGERTIGHT PEEK 10-32
803260
TUBING PEEK (IN) 2EA UV6000LP
703950 803113 803264
TUBING PEEK (OUT) 2EA UV6000LP External Run/Auto Zero/Analog Signal Cables Filter Wheel for linearity calibration
Back to Main
Extra Description
Part of Flowcell Assembly 803237-01and 803265 Part of Flowcell Assembly 803237-01and 803265 Part of Flowcell Assembly 803237-01and 803265
PCBs
F9060-010 F9030-010 803212 F3027-010
F9060-040 60052-61010S
This part number should be used with Communications PCB ( also known as converter PCBA) Xcalibur software version 1.2 only PCB ASSY,FRONT PNL LED LAMP PWR SPLY PCB UV6000LP INSULATOR, PCB This part number should be used with Xcalibur software version 1.2 SP1 and greater, and Chromquest 4.X ASSEMBLY,CONVERTER,PCBA,PDA,CQ4,XCAL1.3 CPU PCB
76472353.xls.ms_office
Surveyor PDA
111
Surveyor PDA Part Number 108052 803247 126078 126079 802259 A3538-010 A3638-010 60053-97107 703909 703903 EXF3000-010
803237-01 803265
Description Deuterium Lamp Assembly (pre-aligned) Tungsten-halogen (W ) Lamp Assembly (pre-aligned) Fuse, T3.15 A (5 x 20 mm) (for 100/115 V operation) Fuse, T1.6 A (5 x 20 mm) (for 230 V operation) Backpressure regulator 9 pin to RJ-45 adapter Cable 4-PIN RJ45 SURVEYOR LC PDA Plus HARDWARE Manual WINDOW,COMBINER CELL CLAMP 10MM UV6000LP Bench Assembly exchange only Flowcell Assembly, with inlet/outlet tubing and fittings (5 cm Lightpipe) 10 mm flow cell Assembly (1 cm LightPipe)
2522-0285
FITTING FINGERTIGHT PEEK 10-32
803260
TUBING PEEK (IN) 2EA UV6000LP
703950 803113 803264
TUBING PEEK (OUT) 2EA UV6000LP External Run/Auto Zero/Analog Signal Cables Filter Wheel for linearity calibration
Transition board PCB ASSY,FRONT PNL LED LAMP PW R SPLY PCB INSULATOR, PCB CPU PCB Low voltage power supply
LUS
Back to Main
Extra Description
Part of Flowcell Assembly 803237-01and 803265 Part of Flowcell Assembly 803237-01and 803265 Part of Flowcell Assembly 803237-01and 803265
Trace GC Ultra Part Number 31303211 45320031 45320030 45320032 45320033 29033406 29013489 29013488 29013487 29013486 35032423 36502001 36500103 36502001
Description Septum Liner, split , 3 mm Liner, split , 5 mm Liner, splitless , 3 mm Liner, splitless , 5 mm Liner seal Graphite ferrule for 0.2 mm ID column Graphite ferrule for 0.25 mm ID column Graphite ferrule for 0.32 mm ID column Graphite ferrule for 0.53 mm ID column Fixing nut for column Syringe 10 ul, 51 mm needle for packed and split injections Syringe 10 ul, 70 mm needle for splitless injections Syringe 10 ul, 75 mm needle for manual OC injections
76472353.xls.ms_office
Trace GC Ultra
Extra Description SSL injector SSL injector SSL injector SSL injector SSL injector SSL injector SSL injector (detector base SSL injector (detector base SSL injector (detector base SSL injector (detector base SSL injector (detector base
10 ul syringe, fixed needle, suitable for Split injections 10 ul syringe, fixed needle, suitable for Splitless and OC injections 2ml screw top vials, 8mm finish (requires P/N 38606074 caps and P/N 31303217 seal) 8mm plastic screw top caps 8mm teflon faced seals Gas tight syringe 1.0 capacity, without plunger Gas tight syringe 2.5 capacity, without plunger Gas tight syringe 5.0 capacity, without plunger Gas tight syringe 1.0 capacity, with plunger and adapter Gas tight syringe 2.5 capacity, with plunger and adapter Gas tight syringe 5.0 capacity, with plunger and adapter 10 ml crimp top vials, 20 mm finish (requires 20 mm aluminum caps and seals) 20mm aluminum crimp top caps with butyl rubber seals for low temperature applications
76472353.xls.ms_office
TriPlus Autosampler
Back to Main
115
Quantum AM
Back to Main
This instrument is labled simply "TSQ Quantum AM" on the front. We call it the "Classic AM" Part Number 00106-10498 00106-10499 00106-10502 00106-10504 00107-11002 00107-12750 00108-02-00002 00301-22924 00301-22925 00960-01-00007 70111-20100 70111-20656 70111-20657 70111-61051S 97055-20442 EX00108-02220
SAP Description TUBING FUSED SI 150U X 390U TUBING FUSED SI .10IDX .19 TUBING FUSED SI .05IDX .19 TUBING FUSED SI .1ID X .363OD O-RING, 2.625. ID, 3/32 W , AS-146 VITON O-RING,0.3ID, D, X0.064W,KALREZ, CMPD;4079 FILTER,MIST, ELIM.PUMP-ACC, EDWARDS HAZ ,MAT POLYTYROSINE 1-3-6 STD LIQUID HAZ ,MAT POLYTYROSINE 1-3-6 STD SOLID KIT, DRAIN, OIL RETURN CAPILLARY 65MM X 0.5MM ID. NEEDLE, METAL, 32 GA.3.14"LG ESI NEEDLE, METAL, 34 GA.3.140"LG ESI PCB ASSY SOURCE SEAL, RING, GRAPHITE VESPEL PUMP CARTRIDGE, LEYBOLD TURBO, 220L/S
Ion Source PCB DC Rod Driver PCB Front Panel PCB CID/Argon Valve Interconnect PCB RF Amplifier PCB Divert Valve PCB
76472353.xls.ms_office
Quantum AM
Alt Description
Exchange turbo pump core
all Quantums exept the Accurate Mass
116
Quantum Classic
Back to Main
This instrument is labled simply "TSQ Quantum" on the front. We call it the "Classic" Part Number 00106-10498 00106-10499 00106-10502 00106-10504 00107-11002 00107-12750 00108-02-00002 00301-22924 00301-22925 00960-01-00007 70111-20100 70111-20119 70111-20287 70111-20288 70111-61051S 70111-63090
SAP Description TUBING FUSED SI 150U X 390U TUBING FUSED SI .10IDX .19 TUBING FUSED SI .05IDX .19 TUBING FUSED SI .1ID X .363OD O-RING, 2.625. ID, 3/32 W , AS-146 VITON O-RING,0.3ID, D, X0.064W,KALREZ, CMPD;4079 FILTER,MIST, ELIM.PUMP-ACC, EDWARDS HAZ ,MAT POLYTYROSINE 1-3-6 STD LIQUID HAZ ,MAT POLYTYROSINE 1-3-6 STD SOLID KIT, DRAIN, OIL RETURN CAPILLARY 65MM X 0.5MM ID. COVER, PROBE MOUNT, QUANTUM NEEDLE, METAL, 32 GAUGE, ESI NEEDLE, METAL, 34 GAUGE, ESI PCB ASSY SOURCE CABLE, ASSY, HIGH VOLTAGE, SOURCE
97055-20442 EX00108-02220 OPTON-20004 OPTON-20005
SEAL, RING, GRAPHITE VESPEL PUMP CARTRIDGE, LEYBOLD TURBO, 220L/S HIGH FLOW METAL NEEDLE LOW FLOW METAL NEEDLE
Fluorescent Detectors FL2000/ FL3000 Part Number A5256-010S 9550-0204S 9551-0144 9551-0160-01 A5246-010 4802-0031 4802-0027 5708-0091
Description FL3000 flowcell Standard cell Xenon lamp Xenon lamp socket Lamp socket for FL3000 Extended range PMT,200-800nm Standard range PMT, 200-650nm PMT for FL3000 standard range, 200-600nm
FL3000 only
PCBs 9852-0010 A9980-010 9851-0030 B9010-010S
Motherboard/CPU PCB Motherboard/CPU PCB Analog PCB Digital PCB
FL2000 only FL3000 only FL2000/FL3000 FL2000/FL3000
76472353.xls.ms_office
UV & FL Detectors
Extra Description FL3000 only
FL3000 only
118
Frequently used parts for making LC-M Part
Part Description
Ferrule, Kel-F, 0.027 in. ID, Upchurch Scientific® (brown) Ferrule, Kel-F, 0.012 in. ID, Upchurch Scientific (clear)
Safety Sleeve Kit Tube, Teflon, 0.03 in. ID x 1/16 in. OD TUBING FUSED SI .05IDX .19
70005-62015 00301-22915 00106-10502
TUBING FUSED SI .10IDX .19 TUBING FUSED SI .1ID X .363OD TUBING FUSED SI 150U X 390U Tubing, fused-silica, 0.1 mm ID x 0.190 mm OD Tubing, fused-silica, 0.1 mm ID x 0.4 mm OD Tubing, PEEK, 0.005 in. ID x 1/16 in. OD
Tubing, PEEK, safety sleeve (red) Tubing, PVC, unreinforced, 3/8 in. ID (clear)
00301-22806 00301-22895
LC-MS Fittings
120
Back to Main More Description
(used with the PEEK safety sleeve) (used with blunt-tip, 32-gauge stainless steel needle included in Metal Needle Kit) clear ferrule for fused silica ESI sample tube (tubing has 0.190mm OD) (used with the Teflon tubing and (red) PEEK tubing) (for use with fused-silica infusion line) (used to connect the (red) PEEK tubing and the sam ple loop to the divert/inject valve)
part of ESI fused silca sample tube connection (used with Ferrule 00101-18114 and ). Screws into 00101-18080 (fitting on back of ESI). See diagram at bottom.
fits the plastic ferrules above: 00101-18119, 00101-18116, 00101-18144, 00101-18120 (used with blunt-tip 32-gauge stainless steel needle, included in Metal Needle Kit)
(used with PEEK safety sleeve) (used to connect the (red) PEEK tubing and the sam ple loop to the divert/inject valve)
(for use with fused-silica infusion line) (used with the Teflon tubing and (red) PEEK tubing) (used with blunt-tip, 32-gauge stainless steel needle included in Metal Needle Kit) (used with the PEEK safety sleeve) (used to connect the (red) PEEK tubing and the sam ple loop to the divert/inject valve) 76472353.xls.ms_office
LC-MS Fittings
121
Back to Main use with 1/4 28 nuts and 1/8" tubing, ss lock ring is a component of the ferrule. Orientatio nof this ring is important for a good seal. One face is flat and the other beveled. (used with blunt-tip 32-gauge stainless steel needle, included in Metal Needle Kit) (used with PEEK safety sleeve) (used with (red) PEEK tubing) (used with (red) PEEK tubing). Screws into 18080.
1/4" 28 nut for 1/8" tubing. Superflangeless fittings are a more robust reverse ferrule system. ESI ground union, stainless steel, ground point (contains a blunt-tip, 32-gauge stainless steel needle; ferrules; PEEK adapter union; LC union; and Metal Needle Safety Insulator) (used to connect the (red) PEEK tubing and the sam ple loop to the divert/inject valve) (contains the PEEK™ safety sleeve and ferrules for use with the
fused-silica sample tube) (for use with syringe needle and LC union)
(fused-silica sample tube and fused-silica capillary tube) (infusion line) (used to cover the fused-silica sample tube and fused-silica capillary tube) (API probe drain tube)
METAL NEEDLE SAFETY INSUL TUBING PVC UNREINF'CLR 3/8I INSTL.INSTR.METAL NEEDLE A FTG HPLC UNION .01 ORFC P FERRULE .012ID KEL-F HPLC FTG HPLC UN METAL NEEDLE NEEDLE,32ga,SS,5.65"L,BLUNT FTG HPLC ADPTR 10-32x1/4-28 CONTAINER,SHIPPING METAL CONTAINER,TUBE,1/4x2.5 OL
FTG FINGERTIGHT 2 UPCHUR CONTAINER,SHIPPING METAL MANUAL,INSTALL INSTR,LOW CONTAINER,TUBE,1/4x2.5 OL FERRULE .008ID KEL-F HPLC FTG,UNION,HPLC,ZDV,BODY0. FTG HPLC UN METAL NEEDLE NEEDLE,METAL 34GAUGE,ESI BINDER,SOFT COVER,DOUBLE COVER SHEET,MANUAL,LOW INSTALLATION INSTRUCTIONS
OPTON-53010 HESI II High Flow Metal Needle K 70005-60155 Needle insert, 32 gauge, HESI II OPTON- 53011
HESI II Low Flow Metal Needle Ki
70005-60180 Needle insert, 34 gauge, HESI II 76472353.xls.ms_office
Metal Needle Kits
123
etal Needle Kits
Back to Main
Alt Description
The high flow needle for the Ion Max source is part number OPTON-53003. This is for use with the current ESI probe (shipping on all Ion Max products) but will not work on the old style Ion Max ESI probe. This T his means that Quantum instruments shipped prior to August 2004 will not be able to use this part until their probes have been upgraded. Range of flow rates is 5uL/min to 400uL/min ATOR D PI-2 EK EEK EL NEEDLE KIT /1/4 NAT PLUG The low flow needle for the Ion Max source is part number OPTON-30004. This is for use with the current ESI probe (shipping on all Ion Max products) but will not work on the old style Ion Max ESI probe. This T his means that Quantum instruments shipped prior to August 2004 will not be able to use this part until their probes have been upgraded. There may also be 1 or 2 LTQ instruments that shipped with the old probe. Range of flow rates is 500nL/min to 10uL/min H NEEDLE KIT LOW NEEDLE 34G /1/4 NAT PLUG 10"ID,NAT,PEEK EEK TANG,TF LOGO LOW METAL NEEDLE -LOW FLOW KIT
OPTON-20034 H-ESI Metal Needle Kit contains both a 32-Gauge High Flow Metal Needle Kit that is recommended for LC flow rates between 5 µL/min to 400µL/min (the High Flow Metal Needle Kit contains 32gauge, 30µmID, 7.44-in needle P/N 97055-20564) and a 34-Gauge Low Flow Metal Needle Kit that is recommended for LC flow rates between 500nL/min to 10µL/min (the Low Flow Metal Needle Kit contains 34gauge, 30µmID, 7.44-in needle P/N 97055-20565)
it This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. t This is the assembly with metal capillary and fittings. We do not sell just the metal capillary. 76472353.xls.ms_office
Metal Needle Kits
124
Used in all ESI Probes in Ion Max Ion sources. This includes: TSQ Quantum Ultra Series (with and without Accurate Mass), TSQ Q uantum Discovery MAX, LCQ Advantage Max, LCQ Deca XP Max, LTQ series, LXQ, LCQ Fleet
Used in all ESI Probes in Ion Max Ion sources. This includes: TSQ Quantum Ultra Series (with and without Accurate Mass), TSQ Q uantum Discovery MAX, LCQ Advantage Max, LCQ Deca XP Max, LTQ series, LXQ, LCQ Fleet
Used in all ESI Probes in Ion Max Ion sources. This includes: TSQ Quantum Ultra Series (with and without Accurate Mass), TSQ Q uantum Discovery MAX, LCQ Advantage Max, LCQ Deca XP Max, LTQ series, LXQ, LCQ Fleet
Xcalibur 2.0.7 Core Software (5 copies for this price) Xcalibur 2.0.7 UPGRADE from Xcalibur 2.0 and later (5 Copies for this price) Xcalibur 2.0.7 UPGRADE from Xcalibur 1.4 SR1 or earlier (5 copies for this price) Xcalibur 2.0 SR2 Core & LC Devices 1.4 & Software Licenses (5 copies for this price) Xcalibur 2.0 SR2 Core & LC Devices 1.4 UPGRADE (from Xcalibur 2.0 or 2.0 SR1) & Software Licenses (5 Copies for this price) Xcalibur 2.0 SR2 Core & LC Devices 1.4 UPGRADE (from Xcalibur 1.4 SR1 or earlier) & Software Licenses (5 copies for this price) Xcalibur 1.4 SR1 Core & LC Devices & Software Licenses - Requires Windows XP and Office XP (5 copies for this price) Xcalibur 1.4 SR1 Core & LC Devices UPGRADE (from any previous version) & Software Licenses - Requires Windows XP and Office XP (5 copie Combined Current Versions of Xcalibur, LTQ Driver, MSQ Driver, Quantum Driver, LC Devices Drivers, and LCquan (5 Copies for this price) LC Devices - Latest Version
ARE OPTIONS - continued TSQ for Xcalibur 1.4 from Xcalibur 1.1 or 1.2 - Requires Windows XP and Office XP (5 copies for this price) TSQ for Xcalibur 1.4 from Xcalibur 1.3 - Requires Windows XP and Office XP (5 copies for this price) LCQ 2.0 software upgrade - Includes Xcalibur 2.0 core - Requires Windows XP Service Pack 2 and Office XP or 2003 (5 copies) TSQ Quantum 1.5 software. Requires Xcalibur 2.0.6 Xcalibur 1.3 Core Software Licenses - Requires Windows 2000 and Office XP (5 copies for this price) Xcalibur upgrade to 1.3 Core - Requires Windows 2000 and Office XP Xcalibur 1.3 Inst. Control Quantum - Requires Windows 2000 and Office XP Xcalibur 1.3 Inst. Control Upgrade Quantum - Requires Windows 2000 and Office XP Xcalibur 1.3 Manuals Kit Xcalibur Core Software Licenses - Requires NT 4.0 and Office 2000 (5 copies for this price) Xcalibur Core Software, Upgrade - Requires NT 4.0 and Office 2000 Xcalibur Inst. Control, TSQ - Requires NT 4.0 and Office 2000 (5 copies for this price) Xcalibur Inst. Control, TSQ, Upgrade - Requires NT 4.0 and Office 2000 Windows Office 2007 Windows XP Professional
TION SOFTWARE BioWorks 3.3.1 SP1 Software (Xcalibur Included) BioWorks 3.3.1 SP1 Software Upgrade from BioWorks 3.1, 3.1 SR1, 3.2, 3.3 and 3.3.1 - (Xcalibur included) BioWorks 3.3.1 SP1 Software Upgrade from 3.0, SEQUEST or TurboSEQUEST (Xcalibur included) Mascot 2.2. with Bioworks 3.3.1Sp1 (single CPU)- for customers w/o valid Bioworks license Mascot 2.2. with Bioworks 3.3.1Sp1 (dual CPU)- f or customers w/o valid Bioworks license ProMass Deconvolution 2.5 ProMass Deconvolution 2.5 Upgrade from BIOMASS Deconvolution (US Customers) SEQUEST Cluster 3.3.1 Software (Master License PLUS fee per dual-CPU node) SIEVE 1.1.0 Software SIEVE 1.1.0 Upgrade - requires SIEVE 1.0 SIEVE 1.1..0 and BioWorks 3.3.1 SP1 PEAKS Studio 4.5 PEAKS Studio 4.5 and BioWorks 3.3.1 SP1 ProSightPC 1.0 QuickCalc (includes Licenses for 3 installations) LCquan 2.5.6 LCquan 2.5.6 for Citirx MetWorks 1.1 and Mass Frontier 5.0 (includes Xcalibur 2.0.7) MetWorks 1.1 - upgrade to MetWorks 1.0.1 and 1.0 (does not include Mass Frontier) MetWorks 1.1 and Mass Frontier 5.0 upgrade from EITHER any version Metabolite ID OR Mass Frontier (includes Xcalibur 2.0.7) MetWorks 1.1 and Mass Frontier 5.0 upgrade from previous versions of both Metabolite ID AND Mass Frontier (includes Xcalibur 2.0.7) MetWorks 1.1 and Mass Frontier 5.0 DEMO versions MetWorks 1.1 and Mass Frontier 5.0 EMPLOYEE versions
76472353.xls.ms_office
Software
129
Back to Main
Software Mass Frontier 5.0 (includes Xcalibur 2.0.7) Mass Frontier 5.0 upgrade from version 4.0 (includes Xcalibur 2.0.7) Mass Frontier 5.0 upgrade from versions 1-3 (includes Xcalibur 2.0.7) ToxID 1.0
ACCESSORIES HPLASERJET 2420D PRINTER,110V HP LASERJET 2300D PRINTER,220V Additional 4 Port Serial Cable Mass Spectrometer Contact Closure Cable Ethernet communication kit for Agilent 1100 (requires X-calibur 1.3 and Agilent JetDirect Card) Xcalibur HP1100 JetDirect Interface Kit