Native Packet Microwave Solution
5 7 / 3 0 0 C D G
Installation & Cabling Installation Manual Edition 1.0 Confidential
The information contained in this document is subject to change without prior notice.
INTRACOM S.A. TELECOM SOLUTIONS, 2015. All rights reserved. All copyright, intellectual intellectual and and industrial industrial rights in this document document and in the technical technical knowledge knowledge it contains are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners. This document is made available to the end users only for their internal use. No part of this document nor any data herein may be published, disclosed, copied, reproduced, redistributed by any form or means, electronically or mechanically, or used for any other purpose whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS. Information as well as drawings and specifications contained in this document are subject to change without prior notice. All trademarks trademarks and copyrights copyrights mentioned mentioned herein herein are the the property property of INTRACOM S.A. TELECOM TELECOM SOLUTIONS and/or their respective owners. Any rights not not expressly expressly granted herein herein are reserved. reserved. Printed in Greece.
INTRACOM TELECOM 19.7 km Markopoulou Ave., Peania, Athens, GR 19002 T +30 210 667 1000, F +30 210 667 1001 http://www.intracom-telecom.com email ema il (product support ):
[email protected]
The information contained in this document is subject to change without prior notice.
INTRACOM S.A. TELECOM SOLUTIONS, 2015. All rights reserved. All copyright, intellectual intellectual and and industrial industrial rights in this document document and in the technical technical knowledge knowledge it contains are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners. This document is made available to the end users only for their internal use. No part of this document nor any data herein may be published, disclosed, copied, reproduced, redistributed by any form or means, electronically or mechanically, or used for any other purpose whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS. Information as well as drawings and specifications contained in this document are subject to change without prior notice. All trademarks trademarks and copyrights copyrights mentioned mentioned herein herein are the the property property of INTRACOM S.A. TELECOM TELECOM SOLUTIONS and/or their respective owners. Any rights not not expressly expressly granted herein herein are reserved. reserved. Printed in Greece.
INTRACOM TELECOM 19.7 km Markopoulou Ave., Peania, Athens, GR 19002 T +30 210 667 1000, F +30 210 667 1001 http://www.intracom-telecom.com email ema il (product support ):
[email protected]
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Table of Contents
1. Introductio Introduction n ................................... ..................................................... .................................... .................................... .................................... ................................ .............. 1 About this Document Document ................. ........ .................. .................. .................. .................. .................. .................. .................. .................. .................. ................. ........ 1 Safety Safety Precautio Precautions ns .................................... ....................................................... .................................... .................................... ..................................... .................. 2 2. Equipment Equipment Materials Materials .................................. .................................................... .................................... .................................... .................................... .................... 5 Radio Radio Unit Unit ................................... ..................................................... .................................... ..................................... ..................................... ................................ .............. 5 Antennas .................. ......... .................. .................. .................. .................. .................. .................. .................. .................. .................. .................. .................. ................ ....... 9 Power Supply Materials .................................................................................................... 11 Groundin Grounding g ................................... ..................................................... .................................... .................................... .................................... ............................... ............. 16 Lightning & Surge Protectors ............................................................................................ 17 Data Traffic Traffic Material Material ............................ .............................................. .................................... .................................... .................................... ....................... ..... 18 Pole Fastening Material .................................................................................................... 22 Alignment Materials Materials .................. ......... .................. .................. .................. .................. .................. .................. .................. .................. .................. ................ ....... 23 3. Equipment Connections ................................................................................................... 24 4. Recommended Tools ........................................................................................................ 28 5. Installation Prerequisites .................................................................................................. 31 6. Cabling Cabling Overvie Overview w .................................... ...................................................... .................................... .................................... .................................... .................... .. 36 Data and Direct Powering.................. ......... .................. .................. .................. .................. .................. .................. .................. .................. ................ ....... 39 39 Data and External Powering (Power Injector) ................................................................... 40 7. Installation & Cabling (UltraLink – FX80).................. ......... .................. .................. .................. .................. .................. .................. ........... 43 Overview Overview .................................. .................................................... .................................... ..................................... .................................... ................................. ................ 43 Installing Grounding Cable ............................................................................................... 44 Installing Mounting Mounting Kit for UltraLink - FX80 with Flat Antenna................. ......... ................. .................. ................. ........ 46 Installing UltraLink UltraLink - FX80 with Flat Antenna onto Mounting Mounting Kit .................. ......... .................. .................. ............. .... 50 Installing UltraLink – FX80 Cables.................. ......... .................. .................. .................. .................. ................. .................. .................. ............ .... 53 8. Installation of Power Injector (Power over Ethernet) ...................................................... 59 Appendix A: Terminating Ethernet (S-FTP) Cable .............................................................. 67 Appendix B: Terminating Power Supply Cable ................................................................... 75 Appendix C: Terminating Grounding Cable ........................................................................ 77 Appendix D: Installing Mounting Kit Alignment Accessories ............................................ 80 Appendix E: Flat Antenna Polarization Change .................................................................. 82 Appendix E: Receptacles Pin Out ........................................................................................ 88 UltraLink UltraLink FX-80 .................................... ...................................................... .................................... .................................... .................................... ...................... .... 88 PonE .................................... ...................................................... .................................... .................................... .................................... .................................... .................... .. 89
-I-
Table of Contents
(Page intentionally left blank)
-II-
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Equipment Disposal Disposal of old electrical and electronic equipment (applicable through the European Union and other European countries with separate waste collection systems). This symbol, found on this product and any of its parts or on its operating instructions or on its packaging, indicates that electrical and electronic equipment may not be disposed of as unsorted municipal waste. Instead, this product should be handed over to applicable collection points for the recycling of electrical and electronic equipment. By ensuring the correct disposal of this product, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate disposal of this product. By recycling, reusing and other forms of recovery of old electrical and electronic equipment you are making an important contribution to the conservation of natural resources and to the protection of the environment. For more information about the recycling of t his product, please contact your local municipal authorities, municipal waste disposal service or the store where you purchased this product.
Απόρριψη παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών (ισχύει στην Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα χωριστής συλλογής απορριμμάτων). Το σύμβολο αυτό, που απεικονίζεται πάνω στο προϊόν και σε τυχόν εξαρτήματα του ή στο εγχειρίδιο οδηγιών του ή στη συσκευασία του, δείχνει ότι οι ηλεκτρικές και ηλεκτρονικές συσκευές, μετά το πέρας της λειτουργίας τους, δεν θα πρέπει να απορρίπτονται μαζί με τα αστικά απόβλητα. Αντίθετα θα πρέπει να παραδίδονται σε κατάλληλα σημεία συλλογής για την ανακύκλωση των ηλεκτρικών και ηλεκτρονικών συσκευών. Διασφαλίζοντας τη σωστή απόρριψη αυτού του προϊόντος, συνεισφέρετε στην πρόληψη πιθανών αρνητικών συνεπειών στο περιβάλλον και την ανθρώπινη υγεία, οι οποίες θα μπορούσαν να προκληθούν από την μη ενδεδειγμένη απόρριψη του προϊόντος. Η ανακύκλωση, επαναχρησιμοποίηση και άλλες μορφές αξιοποίησης των παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών βοηθούν στη διαφύλαξη των φυσικών πόρων και στην προστασία του περιβάλλοντος. Για περισσότερες πληροφορίες σχετικά την ανακύκλωση αυτού του προϊόντος, παρακαλούμε επικοινωνήστε με τις τοπικές δημοτικές αρχές, την υπηρεσία αποκομιδής αστικών αποβλήτων ή το κατάστημα από το οποίο αγοράσατε το συγκεκριμένο προϊόν. Για περισσότερες πληροφορίες, μπορείτε να επικοινωνείτε με το Συ λλογικό Σύστημα Εναλλακτικής Διαχείρισης Αποβλήτων Ηλεκτρικού και Ηλεκτρονικού Εξοπλισμού “Ανακύκλωση Συσκευών Α.Ε.” (www.electrocycle.gr ).
-III-
Table of Contents
Declaration of Conformity Hereby, Intracom S.A. Telecom Solutions declares that the product UltraLink is in compliance with the essential requirements and other relevant provisions of the directive 1999/5/EC, and with the requirements of the RoHS directive 2011/65/EU. For further information, please visit the following URL: http://emc.intracom-telecom.com/
∆ήλωση Συμμόρφωσης Με την παρούσα, η Intracom Α.Ε. Τηλεπικοινωνιακών Λύσεων δηλώνει ότι το προϊόν UltraLink συμμορφώνεται προς τις ουσιώδεις απαιτήσεις και τις λοιπές διατάξεις της οδηγίας 1999/5/EC, καθώς και με τις απαιτήσεις της οδηγίας RoHS 2011/65/EU. Για περισσότερες πληροφορίες γύρω από τη δήλωση συμμόρφωσης, παρακαλούμε επισκεφθείτε την κάτωθι ιστοσελίδα: http://emc.intracom-telecom.com/
-IV-
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
1. Introduction About this Document Scope of document
This document is the Installation & Cabling Manual of the UltraLink -FX80 equipment:
Target Audience
This document is addressed to certified technicians with wireless equipment knowledge and skills concerning the following: • • • • •
Conventions
Outdoor Radio Unit Installation (Pole or Building Wall). Antenna installation. Preparation & Termination of: Ethernet, Power & Grounding cables. Laying and Installing of: Ethernet, Power, Grounding & Fiber Optic Cables. Testing Ethernet cables using Ethernet testers.
This document applies the following conventions: • Bold font is used when describing something very important. • Blue bold font is used for product/devices names and order codes. • Blue underline font is used when describing references / links. This symbol means DANGER. The purpose of this symbol is to warn you that any wrong action can cause bodily injury or even death. This symbol means CAUTION. The purpose of this symbol is to prevent you from performing an action that might result in damage or serious malfunction of the equipment. A note denotes attention to important supplementary information.
1
Chapter 1 Introduction
Safety Precautions GENERAL • Only
trained, authorized personnel should have access to the installed equipment.
•
The equipment premises should be of restricted access.
• Appropriate
labeling should exist at points with high risk of contact with hazardous voltage.
• A
list with emergency phone numbers (e.g. medical assistance numbers) should be hung at easy-to-view positions.
•
Also, recommended are for safety purposes, a fire detection system and fire extinguishers (installed at easy-to-access points) inside the installation premises.
WORKING ON THE BUILDING’S ROOF During stormy weather, do not perform any mechanical assembling or antenna installation/beaming works on the building’s roof. The metal structure of towers / masts is prone to lightning. Continued on next page
2
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Safety Precautions, Continued GROUNDING Never power on any equipment (except indoor AC PoE) unless you have completed the grounding installation as described in this manual. There is risk of equipment failure and / or electrical shock.
Power Injectors devices PROPER CONNECTION Never connect the power injectors OUT receptacle to network switches / routers / laptops. There is risk of network devices failure due to potential power that is carried inside the cable. Connect the OUT receptacle of power injectors to UltraLinkTM – FX80 GbE2 port as described in this manual.
ETHERNET Cable Neither plug in nor unplug the Gigabit Ethernet (S-FTP) cable of UltraLink TM – FX80 when outdoor PonE is powered on and operating unless you have completed the grounding installation as described in this manual. There is risk of equipment failure and / or electrical shock.
LASER RADIATION When using SFP, then the UltraLinkTM –FX80 is a CLASS 1 laser product.
Continued on next page
3
Chapter 1 Introduction
Safety Precautions, Continued AC or DC Power PROPER SWITCHING ON / OFF Never connect or disconnect the power cable to or from the radio unit as well as the power injector when the local power supply sources (AC or DC) is ON. There is risk of equipment failure.
•
LOCAL POWER AC SOURCE Safety requirements require a single pole circuit-breaker to be employed between the local power AC source and UltraLink TM-80 (for AC direct powering) or AC power injector. • The circuit breaker must disconnect the mains phase of the AC power. •
•
LOCAL POWER DC SOURCE •
• •
Safety requirements require a single pole circuit-breaker to be employed between the local power DC source and UltraLink TM-80 (for DC direct powering) or DC power injector. The circuit-breaker must control (open / close) the negative (-) V pole of the power supply. The positive pole of the local power source must be grounded.
For circuit breaker requirements please refer to chapter Installation Prerequisites paragraph Circuit breaker on page 35. •
POWER SUPPLY CABLES (AC/DC) • •
4
Power source cables must be tested for short circuits, open circuit or wrong wiring before installed. The ground wire of the AC power source cable must be connected to the protective earth (ground) point of the mains electricity installation.
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
2. Equipment Materials Radio Unit Introduction
The following packing lists are available: • Models
with a flat antenna included in the package. • Models with no antenna included in the package. Continued on next page
5
Chapter 2 Equipment Materials
Radio Unit, Continued Models with antenna
The available models are shown in the table below: Order Code
Description
UFX80AE-HZAC
With High duplexing transmitter and AC power AC power module.
UFX80AE-LZAC
With Low duplexing transmitter and AC power AC power module.
UFX80AE-HZDC
With High duplexing transmitter and DC power DC power module.
UFX80AE-LZDC
With Low duplexing transmitter and DC power DC power module.
Packing list (1):
Item
Description
1
UltraLinkTM – FX80 radio unit.
2
Flat antenna.
3
Mounting kit (for a pole of 48 mm to 100 mm diameter).
4
Gland for RJ-45 connector, IP67 class (ETH-HOOD ( ETH-HOOD). ).
5
AC power connector, three terminals, solder type, IP68, UV-rated, industrial type (ST-CONN-AC ST-CONN-AC)) (for radio unit equipped with the AC power module) OR DC power connector, two terminals, solder type, IP68, UV-rated, industrial type (ST-CONN-DC ST-CONN-DC)) (for radio unit equipped with the DC power module). module) .
6
Ring terminals (lugs) (M5, tinned copper) for 16mm 2 and 6mm 2 grounding cables.
7
Antenna feeder extension (four screws included).
8
Waveguide gasket for PDR-120 flange of radio unit.
Continued on next page
(1) Items
6
1, 2, 7 and 8 will be pre-assembled.
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Radio Radio Unit , Continued Models without antenna
The available models are shown in the table below: Order Code
Descrip De scrip tion
UFX80A-HZAC
With High duplexing transmitter and AC and AC power power module.
UFX80A-LZAC
With L ow duplexing transmitter and AC and AC power power module.
UFX80A-HZDC
With High duplexing transmitter and DC power DC power module.
UFX80A-LZDC
With L ow duplexing transmitter and DC power DC power module.
Packing list (1):
Item
Description
1
UltraLinkTM – FX80 radio unit.
2
Hook kit for attaching radio unit onto the parabolic antenna mounting bracket.
3
Gland for RJ-45 connector, IP67 class (ETH-HOOD ETH-HOOD). ).
4
AC power connector, three terminals, solder type, IP68, UV-rated, industrial type (ST-CONN-AC ST-CONN-AC)) (for radio unit equipped with the AC power module) OR DC power connector, two terminals, solder type, IP68, UV-rated, industrial type (ST-CONN-DC ST-CONN-DC)) (for radio unit equipped with the DC power module) .
5
Ring terminals (lugs) (M5, tinned copper) for 16mm 2 and 6mm2 grounding cables.
Continued on next page
(1)
Items 1 and 2 will be pre-assembled.
7
Chapter 2 Equipment Materials
Radio Unit, Continued Packing list, continued
UltraLinkTM – FX80 radio unit label:
Item
Description
1
Where: X is E: for embedded flat antenna or S: for stand-alone radio unit U is L: Low L: Low or H: (High) H: (High) Z is TBD W is power module: AC or AC or DC
2
Operating frequency.
3
Bar code.
4
Serial number.
5
QR code, including the following: Bluetooth Mac Address: First BBU’S Mac Address: IP Address: Product Description: Product Code: Serial Number:
8
XX:YY:ZZ:WW:VV:UU XX:YY:ZZ:WW:VV:UU XX:YY:ZZ:WW:VV:UU XX.YY.WW.VV XX.YY.WW.VV UFX80A/E-S-L-Z-VV KZ00-XXX/YY.R0 KZ00-XXX/YY.R0 xxxxxxxxxxxxxxx
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Antennas Flat
Order Code ANT-7080-FL1
Description Flat antenna (mounting kit included).
Packing list:
Item
Description
1
Flat antenna (with plastic cover).
2
Mounting kit (for a pole of 48 mm to 100 mm diameter).
3
Antenna feeder extension (four screws included).
4
Waveguide gasket for PDR-120 flange of radio unit.
5
Silicon tube. Continued on next page
9
Chapter 2 Equipment Materials
Antennas, Continued Parabolic
Item
The following list shows the available parabolic antennas: Order Code / Photo ANT-7080-30P
Description Parabolic antenna of 38 cm diameter (mounting kit included). (1)
A
ANT-7080-60P
Parabolic antenna of 65 cm diameter (mounting kit included). (1)
B
(1) Mounting
kit includes mounting bracket and adaptation plate to mount the UltraLink TM-FX80 radio unit onto the antenna.
10
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Power Supply Materials Topics
This paragraph includes the following topics:
Topic
See Page
Power injectors models
12
Power injectors
13
Power cables
14
Power modules
15
Power connectors
15
Continued on next page
11
Chapter 2 Equipment Materials
Power Supply Materials, Continued Power injectors models
The following models of power injectors are available:
Order Code
Use
Input
Temperature Hardened
Output Power
Indoor
AC
x
75 W
PONE-OD67-AC
Outdoor
AC
70 W
PONE-OD-DC
Outdoor
DC
60 W
POE-ID-AC75
Other types of PoE injectors may be offered based on specific customer needs. Third party PoE injectors need prior interoperability confirmation by Intracom Telecom. UltraLinkTM-FX80 radio can be powered by PoE / PonE only when fitted with the DC power module option. Continued on next page
12
UltraLink-FX80 Installation & Cabling Manual - Edition 1.0
Power Supply Materials, Continued Power injectors
Item
The following table shows the power injectors materials in details: Order Code / Photo POE-ID-AC75
A
PONE-OD67-AC
B
Description Indoor power injector -20°C to +40°C (operation), 90 VAC to 264 VAC, 47 Hz to 63 Hz, 75 W. AC power cord (EU plug) (1) is included. PonE injector, outdoor, wall mount, temperature hardened, -40°C to +55°C (operation), 90 VAC to 264 VAC, 47 Hz to 63 Hz, 70 W, IEC 60529 / IP67 class. Ethernet cable glands and power connector are included in the unit package. AC power cable should be ordered separately. Installation: • For
wall installation, 4 x screws and wall plugs are included in the unit package.
• For pole installation, a bracket and
accessories (INSTPONE-PL2) should be ordered.
PONE-OD-DC C
PonE injector, outdoor, wall mount, -50°C to +65°C (operation), 40 VDC to 60 VDC, 1.8 A max, 60 W. DC power cable should be ordered separately. Installation • For wall installation, 4 x screws and wall plugs are included in the unit package. For pole installation, a bracket and accessories (INST-PONE-PL) should be ordered. Grounding An M3 grounding screw is pre-installed on the unit for connection of 6 mm2 grounding cable. Lightning & Surge Protection Embedded in the unit. •
Continued on next page
(1)
Other plug types can be made available upon customer request.
13